Operation
B
GX2 EA1000C*/* Multi-Wavelength DWDM 1550 nm Laser Transmitter
•
User Guide
40
589569-001-a
Operating the GX2-EA1000C*/* with the Optional SDU
You can control and operate the GX2-EA1000C*/* using the optional SDU with display.
This includes selecting any of the previously referenced control modes and the ability to
monitor the numerous parameters and alarm conditions within the GX2-EA1000C*/*.
Appendix B, “Menus” provides the GX2-EA1000C*/* SDU menu structure and
information on how to use the optional SDU with display.
Downloading New Firmware
The GX2-EA1000C*/* can store up to two sets of firmware programs, which you can
download through the network management system. When the download is complete,
the GX2-EA1000C*/* uses the new firmware for each subsequent boot up. The operator
also has the option of selecting and using any stored set of firmware code at each boot
up.
The network management system enables the operator to view the following
information about the firmware programs stored in the GX2-EA1000C*/*:
•
Firmware revision level
•
Firmware code CRC
•
Which set of firmware will run at the next boot up
The operator has the option of selecting a specific module or all modules of the target
type for download. After all options are selected, the operator can initiate the download.
To download firmware, the network management system must be running and
communicating with the GX2-CM100B. The GX2-CM100B and the network management
system perform the following tasks to download the new firmware:
•
The network management system reads the firmware download file selected by the
operator and verifies the program code CRC. The software reads the target module
type and firmware revision to be downloaded from the file and displays this
information for operator verification.
•
The network management system transfers the download firmware and selected
options to the GX2-CM100B. The GX2-CM100B verifies that the firmware was
transferred correctly and that the selected options are valid. If the GX2-CM100B
detects any errors it responds with an error message to the network management
system. From this point on, the firmware download is handled exclusively by the
GX2-CM100B.
•
Following firmware verification, the GX2-CM100B begins the firmware download to
the target modules. It monitors the programming of new firmware and reports any
errors. It also sends a message informing the network management system that the
firmware download was successful.
•
The GX2-CM100B is now ready to reset the GX2-EA1000C*/* to run the new
firmware program. The operator can determine whether the reboot is immediate or
occurs at a later time following the issuance of a reset command. This option
enables the operator to choose between immediate, delayed, or scheduled reboots.