Installation and Setup
B
GX2 EA1000C*/* Multi-Wavelength DWDM 1550 nm Laser Transmitter
•
User Guide
21
589569-001-a
Inserting the SC/APC Connector
Before inserting the GX2-EA1000C*/* into the GX2-HSG*, insert the interface fiber
jumper SC/APC connector into the optical bulkhead fitting. It is recommended that you
use a short optical jumper for initial GX2-EA1000C*/* installation. This provides greater
flexibility for installation and can be used to verify the optical output power after the unit
is installed.
To insert the SC/APC connector into the optical bulkhead fitting:
1.
Carefully open the shutter of the optical bulkhead fitting.
2.
Align the key on the SC/APC connector with the mating key slot of the optical
bulkhead fitting. Figure 11 illustrates proper SC/APC alignment with the optical
bulkhead fitting:
Figure 11: Inserting the SC/APC connector
3.
Insert the SC/APC connector into the optical bulkhead fitting.
4.
Push the SC/APC connector into the optical bulkhead fitting until it snaps in place.