LD-G-1 / LD-W-1
English
Page 33
!
FAQ
§
Parts are getting too hot and/or start to smoke.
Disconnect the system from the mains immediately!
Possible cause: one or more connections are soldered incorrectly.
à
Check the connections.
Possible cause: The connection of the motor is connected to
locomotive ground.
à
Disconnect the connection from locomotive ground.
§
The locomotive lighting does not correspond to its direction of travel.
Possible cause: The forward and backward light connections have
been exchanged.
à
Check the connections.
Possible cause: The connections of the motor to the points X11 and
X12 have been exchanged.
à
Exchange the connections.
§
A lamp flickers (this is not a defect).
Possible cause: The lamp is connected with one side to locomotive
ground.
à
If you do not want the lamp to flicker, disconnect it from locomotive
ground, insulate it and connect it to the return conductor (point X3).
§
The locomotive does not run.
Possible cause: The locomotive address is not set correctly.
à
Check the solder bridges (if necessary with a magnifiying glass).
If you cannot find the problem, please return the decoder for repair
(address on the cover page).