English
LD-G-1 / LD-W-1
Page 26
mode the velocity of all speed levels is reduced to ca. 50 % compared
to the standard velocity. The accessories connected to the output
switched by the auxiliary function F4 are switched together with the
shunting gear. As soon as the shunting gear is switched on, any
acceleration or brake delay settings are deactivated.
By attaching a solder bridge the shunting gear can be deactivated
permantly.
Restrictions in Motorola I format
The auxiliary functions F1 to F4 are not available in Motorola I format.
It is possible to control one accessory via the function "function"
according to the direction of travel.
Technical specifications
Data format
Motorola I and II
Supply voltage
12-22 Volt digital voltage
Current consumption
(without connected loads)
ca. 10 mA
Max. current for motor
1.000 mA
Max. current per function output
500 mA
Max. total current
1.500 mA
Protected to
IP 00
Ambient temperature in use
0 - + 60° C
Ambient temperature in storage
-10 - + 80° C
Comparative humidity allowed
max. 85 %
Dimensions
ca. 25 x 17 x 8 mm
Weight
ca. 5 g
Checking the package contents
Check the contents of the package for completeness:
§
1 module
§
1 manual