XBOOT
Transfer Data Bootstrap Mode
4.6.19 Transfer Data Bootstrap Mode
XBOOT [<address1> [<address2>]]
where:
<address1>
Starting address.
<address2>
Ending address.
The XBOOT command loads/transfers a block of data from address1 through address2 via the
serial communications interface (SCI) to another MC68HC11 MCU device which has been reset
in the bootstrap mode. A leading control character of $FF is sent prior to sending the data block.
This control character is part of the bootstrap mode protocol and establishes the baud rate for the
rest of the transfer.
If only one address is provided, the address will be used as the starting address and the block size
will default to 256 bytes. If no addresses are provided, the block of addresses from $C000
through $C0FF is assumed by the BUFFALO monitor program.
NOTE
The MC68HC11A8 MCU requires a fixed block size of 256 bytes
for bootloading while the MC68HC11E9 MCU can accept a
variable length block of 1 to 512 bytes.
The XBOOT command generates SCI transmitter output signals at 7812.5 baud which are
intended for another MC68HC11 MCU device operating in the bootstrap mode. These signals
appear as nonsense data to the terminal display used for normal communication with the EVBU.
After using the XBOOT command the EVBU must be reset by pressing the reset switch S1
before normal communications can resume.
Summary of Contents for M68HC11EVBD
Page 4: ......
Page 92: ...HARDWARE DESCRIPTION 5 4 M68HC11EVBU D ...
Page 101: ...SUPPORT INFORMATION M68HC11EVBU D 6 9 Figure 6 2 EVBU Schematic Diagram Sheet 1 of 3 ...
Page 102: ...SUPPORT INFORMATION 6 10 M68HC11EVBU D ...
Page 103: ...SUPPORT INFORMATION M68HC11EVBU D 6 11 Figure 6 2 EVBU Schematic Diagram Sheet 2 of 3 ...
Page 104: ...SUPPORT INFORMATION 6 12 M68HC11EVBU D ...
Page 105: ...SUPPORT INFORMATION M68HC11EVBU D 6 13 Figure 6 2 EVBU Schematic Diagram Sheet 3 of 3 ...