background image

 

 
 
 
Motorola, Inc. 
101 Tournament Drive 
Horsham, PA 19044 

www.motorola.com/broadband

 

 
 

 
04.03.07 
Rev 8 

 

 

MOTOROLA, the Stylized M Logo, STARLINE, Mini-Bridger, and LIFELINE are registered in the US Patent & Trademark Office. 

All other product or service names are the property of their respective owners. 

© 

Motorola, Inc. 2006. All rights reserved. 

 

Specifications are subject to change without notice. 

 

 

5

 

Model 

Description 

Motorola 

Part Number 

Qty 

per 
MB 

MB100S-2HQXH-F 

5-40 / 52-1003 MHz S-split, two output, 42 dB high gain forward, QAM ADU 609.00 MHz 
gain control, 14 dB internal slope, high gain return, full station 

721000-001-00 

 

MB100S-2HAXH-F 

5-40 / 52-1003 MHz S-split, two output, 42 dB high gain forward, ADU 499.25 MHz gain 
control, 14 dB internal slope, high gain return, full station 

721000-002-00 

 

MB100S-2HTXH-F 

5-40 / 52-1003 MHz S-split, two output, 42 dB high gain forward, TDU gain control, 14 dB 
internal slope, high gain return, full station 

721000-003-00 

 

MB100S-2HXXH-F 

5-40 / 52-1003 MHz S-split, two output, 42 dB high gain forward, manual gain control, 14 dB 
internal slope, high gain return, full station 

721000-004-00 

 

MB100S-1HXXH-F 

5-40 / 52-1003 MHz S-split, one output, 42 dB high gain forward, manual gain control, 14 dB 
internal slope, high gain return, full station 

721000-005-00 

 

MB100S-2HSXH-F 

5-40 / 52-1003 MHz S-split, two output, 42 dB high gain forward, QAM ADU 711.00 MHz 
gain control, 14 dB internal slope, high gain return, full station 

721000-021-00  

MB100S-2HXXH-E15 

5-40 / 52-1003 MHz S-split, two output, 42 dB high gain forward, manual gain control, 14 dB 
internal slope, high gain return, 15A electronics module only (no housing) 

721000-006-00  

MB2-100SH  
(“vanilla” model) 

5-40 / 52-1003 MHz S-split, 2-output, 42 dB high gain forward, manual gain control, 14 dB 
internal slope, no return, standard surge arrestor (no FTEC), full station 

535746-001-00  

MB100K-2HQXH-F 

5-42 / 54-1003 MHz K-split, two output, 42 dB high gain forward, QAM ADU 609.00 MHz 
gain control, 14 dB internal slope, high gain return, full station 

721000-010-00  

MB100K-2HAXH-F 

5-42 / 54-1003 MHz K-split, two output, 42 dB high gain forward, ADU 499.25 MHz gain 
control, 14 dB internal slope, high gain return, full station 

721000-011-00  

MB100K-2HTXH-F 

5-42 / 54-1003 MHz K-split, two output, 42 dB high gain forward, TDU gain control, 14 dB 
internal slope, high gain return, full station 

721000-012-00  

MB100K-2HXXH-F 

5-42 / 54-1003 MHz K-split, two output, 42 dB high gain forward, manual gain control, 14 dB 
internal slope, high gain return, full station 

721000-013-00  

MB100K-1HXXH-F 

5-42 / 54-1003 MHz K-split, one output, 42 dB high gain forward, manual gain control, 14 dB 
internal slope, high gain return, full station 

721000-014-00  

MB100K-2HSXH-F 

5-42 / 54-1003 MHz K-split, two output, 42 dB high gain forward, QAM ADU 711.00 MHz 
gain control, 14 dB internal slope, high gain return, full station 

721000-027-00  

MB100K-2HXXH-E15 

5-42 / 54-1003 MHz K-split, two output, 42 dB high gain forward, manual gain control, 14 dB 
internal slope, high gain return, 15A electronics module only (no housing) 

721000-015-00  

MB2-100KH  
(“vanilla” model) 

5-42 / 54-1003 MHz K-split, 2-output, 42 dB high gain forward, manual gain control, 14 dB 
internal slope, no return, standard surge arrestor (no FTEC), full station 

535746-002-00  

MB100A-2HXXH-F-R 

5-65 / 85-1003 MHz A-split, 2-output, high gain, manual gain control, standard 14 dB slope, 
high gain return, full station, RoHS compliant – 

AVAILABLE Q2 2007

 

821000-001-00 

 

MB100J-2HXXH-F-R 

5-55 / 70-1003 MHz A-split, 2-output, high gain, manual gain control, standard 14 dB slope, 
high gain return, full station, RoHS compliant – 

AVAILABLE Q2 2007

 

821000-003-00 

 

Required Accessories 

SFE-100-0 
SFE-100-1 to -22 
SCS-1 to SCS-10 

Starline Forward 1003 MHz equalizer (0 dB)  -or- 
Starline Forward 1003 MHz equalizer (values 1 to 22 dB in 1 dB steps) -or- 
Starline Cable Simulator (values 1 to 10 dB in 1 dB steps) 

527333-001-00 

527296-001 to -022 
477888-001 to -010 

SRE-*-* 

Starline Return Equalizer, 5-40 MHz (S-split), 5-42 (K-split), 5-55 (J-split), 5-65 (A-split), 
values 0-12 dB in 1 dB steps for S-split (2 dB steps for all other frequency splits) 

478176-XXX-00 1 

JXP-*B 

Plug-in attenuator/pad (values 0 to 26 dB, in 1 dB steps) 
 

474011-XXX-00 

 

9  

(dual 

output) 

Optional Accessories 

SP100 
DC100/8 
DC100/10 
DC100/12 

Splitter (1 GHz) to activate third output -or- 
Directional Coupler (1 GHz) to activate third output (8 dB) 
Directional Coupler (1 GHz) to activate third output (10 dB) 
Directional Coupler (1 GHz) to activate third output (12 dB) 

529863-001-00 
529864-001-00 
529864-002-00 
529864-003-00 

 
 

MB100 Ordering Information 

Summary of Contents for MB100

Page 1: ...con and competing GaAs technology E GaAs distortion performance remains linear at significantly higher output levels This higher output level allows the customer to maximize system performance and reduce system costs We encourage our customers to contact their Motorola Account Representative to determine the optimal levels for their systems HIGH GAIN The MB100 also offers high gain which allows th...

Page 2: ...ase and maintenance the amplifier is engineered for compatibility with standard accessories such as attenuators equalizers ADUs or QADUs return amplifiers automotive fuses and FTEC crowbar circuits For an optional third output the MB100 utilizes splitters model SP100 and directional couplers model DC100 The SP100 DC100 8 DC100 10 and DC100 12 offer superior performance to 1 GHz The MB100 uses modu...

Page 3: ... CTB dBc 9 19 21 76 5 88 XM dB 10 19 68 5 77 CSO dBc 9 11 19 71 81 Test Point all dB 12 Return Loss dB 13 Hum Modulation 12A dBc 14 60 5 10 MHz 70 11 40 MHz Hum Modulation 15A 14 55 5 10 MHz 65 11 40 MHz DC Voltage VDC 15 Current DC mA 16 1610 DC Ripple mV Power Consumption W 48 AC Input Voltage Range VAC AC Current Draw A 17 With Return 90 VAC 0 55 75 VAC 0 68 60 VAC 0 81 53 VAC 0 92 45 VAC 1 08 ...

Page 4: ... in NCTA RECOMMENDED PRACTICES FOR MEASUREMENTS ON CABLE TELEVISION SYSTEMS 11 Composite Second Order distortion refers only to those beat clusters that fall 0 75 MHz and 1 25 MHz above the subject picture carrier CSO beat clusters that have a 0 75 MHz and 1 25 MHz relationship to the subject picture carrier are not included in this specification 12 Test points should be used with GFAL adaptor 13 ...

Page 5: ...ation 721000 011 00 MB100K 2HTXH F 5 42 54 1003 MHz K split two output 42 dB high gain forward TDU gain control 14 dB internal slope high gain return full station 721000 012 00 MB100K 2HXXH F 5 42 54 1003 MHz K split two output 42 dB high gain forward manual gain control 14 dB internal slope high gain return full station 721000 013 00 MB100K 1HXXH F 5 42 54 1003 MHz K split one output 42 dB high g...

Page 6: ...g Guide RF Configuration Gain Level Control Electronics only 15 amp One port QADU 609 00 S E GaAs High Output w 42 dB Gain None ADU 499 25 S TDU Return Gain High 20 dB 5 40 MHz 52 1003 MHz Bandpass Split QADU 711 00 S 5 85 MHz 104 1003 MHz Station Slope 14 dB Fmin 1003 MHz 5 42 MHz 54 1003 MHz 5 65 MHz 85 1003 MHz 5 55 MHz 70 1003 MHz Notes 1 Not all combinations in the ordering guide are availabl...

Reviews: