8- 10
MC68306 USER'S MANUAL
MOTOROLA
8.9 AC ELECTRICAL SPECIFICATIONS—BUS ARBITRATION
(The electrical
specifications in this document are preliminary. See Figures 8-6–8-7)
16.67 MHz
Num
Characteristic
Min
Max
Unit
7
CLKOUT High to Address, Data Bus High Impedance (Maximum)
—
50
ns
16
CLKOUT High to Control Bus High Impedance
—
50
ns
33
CLKOUT High to
BG
Asserted
—
40
ns
34
CLKOUT High to
BG
Negated
—
40
ns
35
BR
Asserted to
BG
Asserted
1.5
6.5
Clks
36
BR
Negated to
BG
Negated
1.5
3.5
Clks
37
BGACK
Asserted to
BG
Negated
1.5
3.5
Clks
37A2
BGACK
Asserted to
BR
Negated
20 ns
1.5
Clks
38
BG
Asserted to Control, Address, Data Bus High Impedance (
AS
Negated)
—
50
ns
39
BG
Width Negated
1.5
—
Clks
47
Asynchronous Input Setup Time
10
—
ns
57
BGACK
Negated to Bus Driven
1
—
Clks
58
BR
Negated to Bus Driven
1
—
Clks
CLK
33
35
BR
BG
AS
DS
R/W
FC2–FC0
A19–A0
D7–D0
47
38
36
58
34
39
47
16
7
Figure 8-6. Bus Arbitration Timing Diagram