Application Deployment for WinCE 5.0 7 - 17
IPL Error Detection
While receiving data, IPL performs many checks on the data to ensure that the data is received correctly. If an error
is detected, IPL immediately aborts the download, and reports the error on an error screen.
Target Disk Full
Build process failed because TCM failed to add file to the image of a disk volume.
Remove some files or increase the disk size.
Hex file is READ ONLY
The Hex image file to be created exists and is read-only. Delete the existing file or
change its attribute.
Error opening the file xxx
with write access
TCM could not open file xxx with write access. Check if file is in use.
Failure creating binary file
TCM failed to open/create an intermediate binary file.
Hex File To load is missing
or invalid
In Load Terminal window, the file selected to load has invalid status.
Could not locate mobile
computer name in TCM.ini
file
While loading the Script Properties window, TCM could not find the TCM.ini section
corresponding to the mobile computer type specified by the current opening script.
Either TCM.ini or the script file is invalid.
Incorrect disk sizes in
TCM.ini file
The total disk size specified in the script does not match the total disk size defined in
the corresponding TCM.ini section. Check if the script is corrupt or the TCM.ini has
changed after the script was created.
INVALID DIRECTORY
In Script Properties window, the selected System File Path is not a valid directory.
One of the disk sizes is
one sector in size
In Script Properties window, one of the disks is too small (one sector in size). This may
cause problem while building images, especially when cushion is enabled. Increase
the disk size.
INVALID VOLUME NAME
In Script Properties window, one of the volume labels is not valid.
Corrupt TCM.INI file!
(Invalid value of
VolumeDivisor)
The VolumeDivisor entry is missing or invalid in the TCM.ini. Reinstall TCM or recover
TCM.ini.
Invalid version of TCM
script file
The TCM script was not created by this version of TCM.
Corrupt or missing
TCM.ini file
TCM could not find TCM.ini file.
FAILED CONNECTION
TO COM PORT (Could
not get status)
While downloading images to mobile computer, TCM failed to connect to the selected
COM port. Check if the COM port is free and is properly configured.
FAILED CONNECTION
TO TERMINAL (Terminal
Not Connected
Properly/Terminal Not
Ready to Receive)
While downloading images, TCM failed to connect to the mobile computer. Check if the
correct flow control protocol is selected and the mobile computer is properly connected
and is in a listening state.
Table 7-3
TCM Error Messages (Continued)
Error
Description/Solution
Summary of Contents for MC909X
Page 1: ...MC909X Mobile Computer Integrator Guide ...
Page 2: ......
Page 3: ...MC909X Integrator Guide 72E 72216 06 Rev A December 2007 ...
Page 6: ...iv MC909X Mobile Computer Integrator Guide ...
Page 24: ...xxii MC909X Integrator Guide ...
Page 150: ...4 42 MC909X Integrator Guide ...
Page 220: ...8 14 MC909X Integrator Guide ...
Page 241: ...Staging and Provisioning 9 21 Figure 9 32 UnHide UI Selection ...
Page 252: ...9 32 MC909X Integrator Guide ...
Page 266: ...10 14 MC909X Integrator Guide ...
Page 300: ...B 24 MC909X Integrator Guide ...
Page 314: ...Glossary 14 MC909X Integrator Guide ...
Page 321: ......