5-4
Computer Group Literature Center Web Site
Remote Start Via the PCI Bus
5
Bits 9 to 15
7 bit command option field. Each command specifies the
particular meaning of each of the command option bits.
Option bits which are unused are considered reserved and
should be written to 0 to ensure compatibility with future
implementations of this interface.
Note
For most commands, bit 9 is used to specify verbose/non-
verbose mode target command processing. In verbose
mode, command related information is printed on the target
console as the host command is processed. Verbose mode is
selected when bit 9 = 0, non-verbose mode is set when bit 9
= 1.
Bits 16 to 31
16 bit data/result field. The meaning of this field is specific to
each command opcode. Refer to
for
error codes.