Chapter 2: Infrastructure Device Installation
May 2008
2-12
category, and therefore must be treated with greater considerations as far as grounding requirements
are concerned.
Since Type B grounding requirements stipulate 5 ohms or less impedance to earth ground, things such
as soil pH, type of grounding rods, size of conductors, and ground enhancing materials must be taken
into account to achieve this goal. To verify the impedance requirements are met, a special
Earth/Ground Resistance Tester (megohmmeter) may be necessary.
•
If the MOTOMESH Duo 4300 Device product is attached to a light arm and the
attachment point meets the Type B grounding requirements, then the grounding stud
attachment point is not required to be used.
To avoid damage to the equipment, adequate grounding for all MOTOMESH Duo
4300 devices is mandatory.
Assembling AC and DC Power
Use the following procedures to assemble a MOTOMESH Duo 4300 Device with AC or DC power.
Additional AC power cable
are detailed in Chapter 3 of this users guide.
US AC Power Assembly
Procedure 2-4 Assembling a US AC Power
European and Australian AC Power Assembly
Procedure 2-5 Assembling a European or Australian AC Power
1
Place the brackets at the desired position on the pole.
2
Adjust the position of the box so that the antenna connectors are positioned vertically. Align the antennas
with the N-type connectors on the box and rotate to close.
3
Insert the cable into the external Ethernet port and tighten the connector to ensure a weatherproof seal.
4
Insert the Power Plug into the 4-pin connector.
1
Place the brackets at the desired position on the pole.
2
Adjust the position of the box so that the antenna connectors are positioned vertically. Align the antennas
with the N-type connectors on the box and rotate to close.
3
Insert the cable into the external Ethernet port and tighten the connector to ensure a weatherproof seal.
4
Insert the Power Plug into the 3-pin connector.
Summary of Contents for MOTOMESH Duo 4300-49
Page 1: ...MOTOROLA MOTOMESH DUO 2 1 4300 Users Guide May 2008 ...
Page 2: ...MOTOMESH DUO 2 1 4300 Users Guide May 2008 ii This page intentionally left blank ...
Page 4: ...MOTOMESH DUO 2 1 4300 Users Guide May 2008 iv This page intentionally left blank ...
Page 8: ...May 2008 viii Blank page intentionally left blank ...
Page 12: ...List of Tables May 2008 xii This page intentionally left blank ...
Page 14: ...List of Procedures May 2008 xiv This page intentionally left blank ...
Page 22: ...Chapter 1 Product Introduction May 2008 1 8 This page intentionally left blank ...
Page 36: ...Chapter 2 Infrastructure Device Installation May 2008 2 14 This page intentionally left blank ...
Page 52: ...Chapter 3 Wiring Instructions May 2008 3 16 Figure 3 35 Finished Power Connector ...
Page 74: ...Chapter 6 Customer Service May 2008 6 4 This page intentionally left blank ...
Page 90: ...Glossary May 2008 Glossary 2 This page intentionally left blank ...