A - 2 MP6000 INTEGRATOR GUIDE
Troubleshooting
Diagnostic LED 7-segment Display - Error and Warning Codes
The MP6000 includes a one character LED display inside the scanner vertical window. This display provides
status and troubleshooting information, as well as scale legal parameters during calibration (only
configurations with a scale).
Status, warning, and error information are communicated via letter(s) and number(s) scrolled one character at
a time in the LED display. When a message completes, the display pauses for two seconds, then repeats the
sequence continuously.
See
Chapter 4, SCALE CALIBRATION (MODELS WITH A SCALE ONLY)
for detailed calibration information,
including calibration errors and warnings.
LED Display Notes
•
-
(dash) indicates normal operating mode.
•
Scale calibration information (see
) has precedence over general warning
messages but not over errors.
•
Scrolling
CAL
(number of calibrations performed) and
PAR
(legal parameter) values display for scale
verification (electronic
seal
).
•
Cxxx
and
Pxxx
scroll when the
Scale Zero
button is held for three or more seconds.
•
An error message displays when a fault condition exists. A power cycle is required. Verify that the
subsystems and auxiliary devices are operational.
•
A warning message displays when a warning condition exists. The power sequence pauses until the
issue is resolved.
•
For scale firmware version # 1.04F (for applicable countries):
•
Scrolling
CAL
(number of calibrations performed) and
PAR
(legal parameter) values display for scale
verification (electronic
seal
), and where required by country legislation, scale approved firmware
version number.
•
Cxxx
and
Pxxx
scroll when the
Scale Zero
button is held for three or more seconds, followed by
x.xx F
(determined by country legislation).
Status Indicator Light
The status indicator light on the MP6000 has three types of displays.
•
Center green: Operating normally.
•
Red warning: The outer two system LEDs are red; the display appears for .25 seconds every five
seconds.
•
Red error: All system LEDs turn red and remain red, overriding any other visual system LED sequences,
until all errors are resolved.
IMPORTANT
are for reference only. Contact your service provider for
any error or warning conditions.
Summary of Contents for MP6000
Page 1: ...MP6000 INTEGRATOR GUIDE ...
Page 2: ......
Page 3: ...MP6000 INTEGRATOR GUIDE 72E 172632 06 Revision A November 2014 ...
Page 7: ...v ...
Page 8: ...vi MP6000 INTEGRATOR GUIDE ...
Page 14: ...xii MP6000 INTEGRATOR GUIDE ...
Page 18: ...viii MP6000 INTEGRATOR GUIDE ...
Page 33: ...PRODUCT OVERVIEW AND FEATURES 1 15 ...
Page 34: ...1 16 MP6000 INTEGRATOR GUIDE ...
Page 41: ...HOST INTERFACES AND CABLE PINOUTS 2 7 USB Device Type continued IBM Table top USB ...
Page 42: ...2 8 MP6000 INTEGRATOR GUIDE USB Device Type continued IBM Hand held USB ...
Page 45: ...HOST INTERFACES AND CABLE PINOUTS 2 11 USB Device Type continued CDC COM Port Emulation ...
Page 55: ...HOST INTERFACES AND CABLE PINOUTS 2 21 RS 232 Host Types continued Standard RS 232 ...
Page 56: ...2 22 MP6000 INTEGRATOR GUIDE RS 232 Host Types continued ICL RS 232 ...
Page 58: ...2 24 MP6000 INTEGRATOR GUIDE RS 232 Host Types continued Wincor Nixdorf RS 232 Mode B ...
Page 59: ...HOST INTERFACES AND CABLE PINOUTS 2 25 RS 232 Host Types continued Olivetti ORS4500 ...
Page 60: ...2 26 MP6000 INTEGRATOR GUIDE RS 232 Host Types continued Omron ...
Page 61: ...HOST INTERFACES AND CABLE PINOUTS 2 27 RS 232 Host Types continued OPOS JPOS ...
Page 62: ...2 28 MP6000 INTEGRATOR GUIDE RS 232 Host Types continued Fujitsu RS 232 ...
Page 63: ...HOST INTERFACES AND CABLE PINOUTS 2 29 RS 232 Host Types continued CUTE 2 ...
Page 72: ...2 38 MP6000 INTEGRATOR GUIDE Third Party Scale continued Disable Third Party Scale 0 ...
Page 74: ...2 40 MP6000 INTEGRATOR GUIDE Third Party Scale LED Pin continued Active High 1 ...
Page 76: ...2 42 MP6000 INTEGRATOR GUIDE Third Party Scale Zero Pin continued Active High 1 ...
Page 79: ...HOST INTERFACES AND CABLE PINOUTS 2 45 IBM Port Addresses None Selected ...
Page 80: ...2 46 MP6000 INTEGRATOR GUIDE IBM Port Addresses continued Hand held Scanner Emulation Port 9B ...
Page 82: ...2 48 MP6000 INTEGRATOR GUIDE IBM Port Addresses continued Tabletop Scanner Emulation Port 17 ...
Page 84: ...2 50 MP6000 INTEGRATOR GUIDE IBM Scale Port Addresses continued Port 6A ...
Page 85: ...HOST INTERFACES AND CABLE PINOUTS 2 51 IBM Scale Port Addresses continued Port 6B ...
Page 86: ...2 52 MP6000 INTEGRATOR GUIDE IBM Scale Port Addresses continued Port 6E ...
Page 90: ...2 56 MP6000 INTEGRATOR GUIDE ...
Page 130: ...3 40 MP6000 INTEGRATOR GUIDE ...
Page 144: ...4 14 MP6000 INTEGRATOR GUIDE Legal Scale Units continued Pounds 1 ...
Page 148: ...4 18 MP6000 INTEGRATOR GUIDE Parameter 996 continued Low Vibration Sensitivity 1 ...
Page 150: ...4 20 MP6000 INTEGRATOR GUIDE Parameter 996 continued Ultra Low Vibration Sensitivity 3 ...
Page 154: ...4 24 MP6000 INTEGRATOR GUIDE ...
Page 188: ...A 8 MP6000 INTEGRATOR GUIDE ...
Page 192: ...B 4 MP6000 INTEGRATOR GUIDE ...
Page 208: ......
Page 209: ......