2-4
Computer Group Literature Center Web Site
Startup and Operation
2
Pre-Startup Checklist
Before you power up the MVME177P system, be sure that the following
conditions exist:
1. Jumpers and/or configuration switches on the MVME177P Single-
Board Computer and associated equipment are set as required for
your particular application.
2. The MVME177P board is installed and cabled up as appropriate for
your particular chassis or system, as outlined in Chapter 1.
3. The terminal that you plan to use as the system console is connected
to the console port (serial port 1) on the MVME177P module.
4. The terminal is set up as follows:
– Eight bits per character
– One stop bit per character
– Parity disabled (no parity protection)
– Baud rate 9600 baud (the default baud rate of many serial ports
at power-up)
5. Any other device that you wish to use, such as a host computer
system and/or peripheral equipment, is cabled to the appropriate
connectors.
After you complete the checks listed above, you are ready to power up the
system.
Summary of Contents for MVME177P
Page 1: ...MVME177P Single Board Computer Installation and Use V177PA IH1 Edition of October 2000 ...
Page 10: ...x ...
Page 12: ...xii ...
Page 14: ...xiv ...
Page 34: ...1 16 Computer Group Literature Center Web Site Hardware Preparation and Installation 1 ...
Page 48: ...2 14 Computer Group Literature Center Web Site Startup and Operation 2 ...
Page 92: ...C 2 Computer Group Literature Center Web Site Network Controller Data C ...
Page 98: ...D 6 Computer Group Literature Center Web Site Disk Tape Controller Data D ...
Page 108: ...Index IN 6 Computer Group Literature Center Web Site I N D E X ...