Setup and Operation
4-9
NTFC Menu
⎯
Modifying the Physical Port Default Settings
To modify the physical port default settings:
1
Select
INTFC
on the MAIN menu and then press
ENT
to display the INTFC menu
illustrated in Figure 4-4:
Figure 4-4
INTFC menu
A
E
F
G
H
I
C
D
B
2
Press or to select the port to configure and then press
ENT
.
3
Use Table 4-4 to set up ports 2, 4, 5, and 6. The table describes the configurable menu items
for these ports.
4
After configuring the menu items, select
UP
and then press
ENT
to display the MAIN menu.
Table 4-4 describes the fields and available options:
Table 4-4
Configuring the physical ports
Key Field
Description
A
INTFC:
Identifies the menu.
B
1 CONSOLE
Displays the internal console settings for
PORT
1. The console port is accessible from
the rear panel. It provides asynchronous communications at 9600 baud and cannot be
reconfigured at the front panel. It is used only for maintenance.
C
2 530/232
Configures the operating parameters for
PORT
2. This port is configured for
asynchronous communications, and the data rate is configured from 300 bps through
19.2 Kbps.
D
3 ENET
Displays the operating parameters for
PORT
3. A display-only field displays the MAC
address; a selection for the Time-To-Live (TTL) setting, a selection for enabling or
disabling IGMP, and a menu selection for the multicast MAC receive address assigned
to the OM 1000 at the factory.
E
UP
Displays the MAIN menu.
F
4
Configures the operating parameters for optional
PORT
4. Configure the data and baud
options as described for
PORT
2, if present. Select async or sync (internal clock,
external clock, or slv on rx clock). The INTFC menu displays UNEQPD if the
communications board is not present and configured. Refer to the
operate.txt
file in
Appendix C, “Initialization Information.”
OM 1000 Installation and Operation Manual