4-30
Setup and Operation
Key Field
Options
Description
H
COMMIT
Commits the current Ethernet output port settings to the OM 1000
database. To store the settings permanently, display the ADMIN menu
and save the settings. This is only displayed when a change is made.
The OM 1000 must then be rebooted before any changes are applied.
Figure 4-20 illustrates the logical Ethernet destination IP address menu:
Figure 4-20
Logical Ethernet destination IP address menu
A
B
C
D
Table 4-15 describes the fields and available options:
Table 4-15
Logical Ethernet destination IP address menu options
Key Field
Options
Description
A
PORT nn
Identifies the logical output port being setup
B
DST-IP 000.000.000.000
through
239.255.255.255
or
255.255.255.255
Sets the destination IP address. Can be either a singlecast IP
address (class A, B, or C), a multicast address (class D), or a
broadcast address (255.255.255.255).
C
UP
Displays the previous menu.
D
MPEG/UDP
1-7
Sets the number of MPEG packets to be transmitted per UDP
packet.
OM 1000 Installation and Operation Manual