Data rate calculations
Chapter 4 Reference information
phn-0896_012v000
4-118
Jul 2010
Table 4-88 Throughput for PTP 600 Full, link symmetry 1:1, link optimization IP
30 MHz
20 MHz
15 MHz
Modulation
Mode
Tx
Rx
Both
Tx
Rx
Both
Tx
Rx
Both
256QAM 0.81
dual
150.01 150.01 300.02 100.06 100.06 200.12 75.37 75.37 150.74
64QAM 0.92 dual
126.39 126.39 252.78 84.30 84.30 168.61 63.50 63.50 127.01
64QAM 0.75 dual
103.28 103.28 206.57 68.89 68.89 137.78 51.89 51.89 103.79
16QAM 0.87 dual
80.35
80.35
160.70 53.60 53.60 107.19 40.37 40.37 80.74
16QAM 0.63 dual
57.76
57.76
115.52 38.53 38.53 77.06 29.02
29.02 58.04
256QAM 0.81
single
75.00 75.00 150.01 50.03 50.03 100.06 37.69 37.69 75.37
64QAM 0.92
single
63.19 63.19 126.39 42.15 42.15 84.30 31.75
31.75 63.50
64QAM 0.75
single
51.64 51.64 103.28 34.45 34.45 68.89 25.95
25.95 51.89
16QAM 0.87
single
40.17 40.17 80.35 26.80 26.80 53.59 20.18
20.18 40.37
16QAM 0.63
single
28.88 28.88 57.76 19.26 19.26 38.53 14.51
14.51 29.02
QPSK
0.87
single 20.09 20.09 40.17 13.40 13.40 26.79 10.09
10.09 20.18
QPSK
0.63
single 14.44 14.44 28.88 9.63 9.63 19.26 7.25 7.25 14.51
BPSK
0.63
single 7.22 7.22 14.44 4.81 4.81 9.63 3.63 3.63 7.25
At zero range. All rates are in Mbit/s.
4Gon www.4Gon.co.uk info@4gon.co.uk Tel: +44 (0)1245 808195 Fax: +44 (0)1245 808299