Data rate calculations
Chapter 4 Reference information
phn-0896_012v000
4-120
Jul 2010
Table 4-89 Throughput for PTP 600 Full, link symmetry 1:1, link optimization TDM
30 MHz
20 MHz
15 MHz
Modulation
Mode
Tx
Rx
Both
Tx
Rx
Both
Tx
Rx
Both
256QAM 0.81
dual
140.87 140.87 281.74 96.01 96.01 192.02 72.92 72.92 145.83
64QAM 0.92 dual
118.69 118.69 237.38 80.89 80.89 161.78 61.43 61.43 122.87
64QAM 0.75 dual
96.99
96.99
193.98 66.10 66.10 132.21 50.20 50.20 100.41
16QAM 0.87 dual
75.45
75.45
150.91 51.43 51.43 102.85 39.06 39.06 78.11
16QAM 0.63 dual
54.24
54.24
108.48 36.97 36.97 73.94 28.08
28.08 56.15
256QAM 0.81
single
70.43 70.43 140.87 48.00 48.00 96.01 36.46
36.46 72.91
64QAM 0.92
single
59.34 59.34 118.69 40.44 40.44 80.89 30.72
30.72 61.43
64QAM 0.75
single
48.49 48.49 96.99 33.05 33.05 66.10 25.10
25.10 50.20
16QAM 0.87
single
37.73 37.73 75.45 25.71 25.71 51.42 19.53
19.53 39.05
16QAM 0.63
single
27.12 27.12 54.24 18.48 18.48 36.97 14.04
14.04 28.07
QPSK
0.87
single 18.86 18.86 37.72 12.85 12.85 25.71 9.76 9.76 19.52
QPSK
0.63
single 13.56 13.56 27.12 9.24 9.24 18.48 7.02 7.02 14.03
BPSK
0.63
single 6.78 6.78 13.56 4.62 4.62 9.24 3.51 3.51 7.02
At zero range. All rates are in Mbit/s.
4Gon www.4Gon.co.uk info@4gon.co.uk Tel: +44 (0)1245 808195 Fax: +44 (0)1245 808299