User Guide: PTP 600 Series
Preparing and connecting cables
phn-0896_012v000
Jul 2010
5-9
Connecting the drop cable to an ODU or LPU
Perform this task to connect the drop cable to an ODU or LPU. This procedure
contains illustrations of an ODU, but it applies in principle to both the ODU and the
LPU.
NOTE
For the ODU drop cable, always use LPU type WB2900B or later. Do not use
LPU type WB2900.
To connect the drop cable with a gland to a unit (LPU or ODU), proceed as follows:
Procedure 5-2 Connect the drop cable with a gland to a unit (LPU or ODU)
1
Insert the RJ45 plug into the socket in the unit, making sure that the
locking tab snaps home.
2
Support the drop cable and gently hand screw the gland body into the
unit until the O ring seal is flush to the unit body.
NOTE
Do not fit the back shell prior to securing the gland body.