Installing the ODU and top LPU
Chapter 5 Installation
phn-0896_012v000
5-16
Jul 2010
Mounting the ODU and top LPU
WARNING
To prevent failure of the assembly, do not over-tighten the bolts.
The ODU must be mounted using the following steps, ensuring that the cable entry is
at the bottom:
Procedure 5-4 Mounting the ODU and top LPU
1
Check the contents of the ODU and LPU boxes.
2
Select the most suitable mounting option for the top LPU and ODU, as
described in
Selecting a mounting option for the top LPU
on page
5-14
.
3
Attach the ODU bracket strap to the pole using M8 x 70 mm bolts, M8
flat washers and M8 coil washers.
If LPU mounting option 1 (back-to-back) has been chosen, mount the
LPU on the bracket bolts. The LPU must be vertical with cable glands
facing downwards.
Tighten to ensure the assembly grips, but can be adjusted on the pole.
4
Use the integral safety loop (
Figure 5-6
) to hoist the ODU up to the
bracket, observing the safety precautions listed in
Checking that it is
safe to hoist the ODU
on page
5-15
.
5
When the ODU is in position, use the safety loop as a fixing point to
secure a permanent lanyard from the supporting structure to the ODU,
as a precaution against mounting failure.
4Gon www.4Gon.co.uk info@4gon.co.uk Tel: +44 (0)1245 808195 Fax: +44 (0)1245 808299