Installing a GPS receiver for PTP-SYNC
Chapter 5 Installation
phn-0896_012v000
5-44
Jul 2010
Figure 5-21 RJ45 and Trimble connector pins
To connect the drop cable to the Trimble GPS receiver, proceed as follows:
Procedure 5-11 Connect drop cable to Trimble GPS receiver
1
Prepare the drop cable end as follows:
Bare back the cable outer and copper screen to 50mm.
Bare back the cable inner to 17mm.
Un-twist the cable pairs.
Strip the individual conductors to 5mm.
2
Fit the adaptor outer, associated boot, and boot insert.