User Guide: PTP 600 Series
Task 4: Configure security
phn-0896_012v000
Jul 2010
6-35
Checking that the unit is in FIPS 140-2 secure mode
The unit is ready to operate in FIPS 140-2 secure mode when both of the following
conditions apply:
•
The FIPS 140-2 capability logo is displayed in the navigation bar (
Figure 1-25
).
•
The FIPS Operational Mode Alarm is not present in the Home page (
Figure 1-26
).
If the FIPS 140-2 capability logo is not displayed in the navigation bar, then return to
Prerequisites for FIPS 140-2
on page
6-25
and check that all prerequisites are fulfilled.
If the FIPS 140-2 Operational Mode Alarm is present in the Home page, take action
depending upon the alarm setting as follows:
•
‘FIPS mode is not configured’ – return to
Starting security wizard
on page
6-26
and check that all Security Wizard settings are correct for FIPS 140-2.
•
‘FIPS mode is configured, but not active’ – return to
Step 6: HTTP and Telnet
settings
on page
6-32
and set the following attributes to ‘No’:
o
HTTP Access Enabled
o
Telnet Access Enabled
o
SNMP Control of HTTP And Telnet
4Gon www.4Gon.co.uk info@4gon.co.uk Tel: +44 (0)1245 808195 Fax: +44 (0)1245 808299