Remote software upgrade by TFTP
Chapter 7 Operation
phn-0896_012v000
7-38
Jul 2010
Remote software upgrade by TFTP
This section describes how to upgrade the PTP 600 software remotely using Trivial
FTP (TFTP) triggered by SNMP.
To perform a remote software upgrade, follow this procedure:
Procedure 7-3 Remote software upgrade
1
Check that the TFTP client is enabled. Refer to
Configuring HTTP, Telnet
and TFTP access
on page
6-110
.
2
Set tFTP attributes as described in
Table 7-11
.
3
Monitor tFTP attributes as described in
Table 7-12
.
4
When the upgrade is complete, reboot the ODU to run the newly loaded
software image as described in
Rebooting
the unit on page
8-27
.
Table 7-11 Setting tFTP attributes
Attribute
Meaning
tFTPServerIPAddress
The IP address of the TFTP server from which the TFTP
software upgrade file Name will be retrieved.
For example, to set the TFTP server IP address for unit
10.10.10.10 to 10.10.10.1, enter this command:
snmpset_d.exe -v 2c -c public 10.10.10.10
.iso.3.6.1.4.1.17713.1.9.5.0 a 10.10.10.1
tFTPServerPortNumber
This setting is optional. The port number of the TFTP
server from which the TFTP software upgrade file name
will be retrieved (default=69).
tFTPSoftwareUpgrade
FileName
The filename of the software upgrade to be loaded from
the TFTP server.
For example, to set the TFTP software upgrade filename
on 10.10.10.10 to "B1095.dld", enter this command:
snmpset_d.exe -v 2c -c public 10.10.10.10
.iso.3.6.1.4.1.17713.1.9.7.0 s B1095.dld