User Guide: PTP 600 Series
Using recovery mode
phn-0896_012v000
Jul 2010
8-25
Resetting IP & Ethernet configuration
To reset IP and Ethernet configuration back to factory defaults from the Recovery
Options page (
2
Figure 8-8
) , proceed as follows:
Procedure 8-18 Reset IP and Ethernet configuration when in recovery mode
1
Select
Reset IP & Ethernet Configuration back to factory defaults
. The
pop up box is displayed. Note the IP address that will be needed to log into
the unit after recovery.
2
Select
OK
. The confirmation pageis displayed.
3
Select
Reboot
. When the ‘Are you sure?’ pop up box is displayed, select
OK
.
4
The unit will now reboot. The unit should now start up in normal mode but
with the IP and Ethernet configuration reset to factory defaults. If the unit
fails to recover, refer to
Test link end hardware
on page
8-2
.
4Gon www.4Gon.co.uk info@4gon.co.uk Tel: +44 (0)1245 808195 Fax: +44 (0)1245 808299