Switch Security
6-11
2. Click the
Configuration
tab.
The MU Intrusion Detection tab consists of the following two fields:
• Collection Settings
• Violation Parameters
3. Within the
Collection Settings
field, set the
Detection Window
interval (in seconds) the switch uses
to scan for MU violations. The available range is from 5 - 300 seconds.
4. Refer to the
Violation Parameters
field
to define threshold values that trigger an alarm:
Violation Type
Displays the name of the violation for which threshold values are set in the MU,
radio and switch columns.
Trigger Against
(Auth, Unauth,
Ignore)
Displays what conditions will trigger the violation parameter against Authorized
APs, Unauthorized APs and Ignored APs. If a violation is triggered by an AP type it
will display with a green check box. If it is not triggered on an AP type it will
display with a red X.
Threshold Values for
Mobile Unit
Set the MU threshold value for each violation type. If exceeded, the MU will be
filtered and displayed within the Filtered MUs screen.
Threshold Values for
Radio
Set the radio threshold value for each violation type. If exceeded, the radio will be
filtered and displayed within the Filtered Radios screen.
Time to Filter
Set the Time to Filter interval (in seconds) the switch uses to filter out MUs defined
as committing a violation. Refer to
Viewing Filtered MUs on page 6-12
to review
the contents of the MUs that have been filtered thus far.
Summary of Contents for RFS Series
Page 1: ...M Motorola RFS Series Wireless LAN Switches WiNG System Reference Guide ...
Page 10: ...TOC 8 Motorola RF Switch System Reference Guide ...
Page 56: ...2 8 Motorola RF Switch System Reference ...
Page 334: ...5 52 Motorola RF Switch System Reference 2 Select the MU Status tab ...
Page 510: ...7 32 Motorola RF Switch System Reference Guide ...
Page 534: ...8 24 Motorola RF Switch System Reference Guide ...
Page 570: ...C 14 Motorola RF Switch System Reference Guide ...
Page 589: ......