2 - 6
RS507 Hands-Free Imager Product Reference Guide
Battery Age Test
The battery age test checks the battery capacity when fully charged. A worn-out battery is considered to have less
than 80% of its nominal capacity. The battery test is simultaneously performed for all batteries inserted into the
charger. It is recommended to perform battery age testing once a month. The age test may take up to 16 hours.
To test the battery(s):
1.
Insert one or more batteries into Charging Bay(s).
2.
Press and hold the Test Button for approximately 3 seconds until the Charge Status LED of each active bay
flashes green.
3.
Refer to the table below when the indication of the Charge Status LED changes.
Charge Status LED
The Charge Status LEDs show the charge status of each Charging Bay:
NOTE
A battery removed during test and re-inserted is excluded from the test but continues normal charging.
Table 2-1
Charge LED - Status Indications
LED Indication
Status
Flashing amber
Charging in progress.
Solid amber
Charging is completed.
Flashing green
Battery age testing in progress.
Flashing red/green
Defective battery or error in charging; re-insert the battery into the bay.
Solid green
Battery age test and charge are completed. Battery is good.
Solid red
Battery age test and charge are completed. Battery capacity is marginal.
Flashing red
Battery age test and charge are completed. Battery is worn out.
Summary of Contents for RS507 Series
Page 1: ...RS507 Hands Free Imager Product Reference Guide ...
Page 2: ...RS507 Hands Free Imager Product Reference Guide 72E 120802 01 Rev B September 2011 ...
Page 11: ...xii RS507 Hands Free Imager Product Reference Guide Glossary Index ...
Page 181: ...7 12 RS507 Product Reference Guide ...
Page 242: ...Appendix C Sample Bar Codes Code 39 UPC EAN UPC A 100 123ABC 0 12345 67890 5 ...
Page 245: ...C 4 RS507 Hands Free Imager Product Reference Guide Maxicode QR Code US Postnet ...
Page 246: ...Sample Bar Codes C 5 UK Postal ...