Document Number: 504834-001
35
Program Processing
Value
PES/Transport Alignment
Yes
Video PID
32 to 8187, Default 32 (Decimal)
Audio PID (Channel 1)
32 to 8190, Default 33 (Decimal)
Audio PID (Channel 2)
32 to 8190, Default 34 (Decimal)
PMT PID
32 to 8190, Default 35 (Decimal)
WST PID
32 to 8190, Default 36 (Decimal)
Allow PID Contention
No
MPEG Program Number
1 to 65535, Default 1 (Decimal)
Transport Stream ID
0 to 65535, Default 1 (Decimal)
Physical
Rack Requirement
Height
1.75” (1 U)
Width 17.3”
Depth 19.8”
Mounting
Rack stackable in standard 19” W x 32” D stack
Important:
SE encoders are stackable, one on top of another, within a rack, without any
spacing requirements. Place each SE encoder in a stable and level position within the
rack and ensure that all front enclosure screws are tightened to 2 ft.-lbs. If multiple SE
encoders are installed in a rack assembly, the operator may choose to have a
certification agency evaluate the condition of the rack.
Elevation(s)
Required Temperature
Sea Level
0 to 40
°
C
5,000 feet Above Sea Level
0 to 37
°
C
10,000 feet Above Sea Level
0 to 34
°
C
Important:
The above temperatures must be measured inside the rack. SE encoders
require sufficient ventilation and air conditioning. To ensure safe operation, proper
airflow must be maintained at all times.
Power
Description
AC Input
115 – 230 VAC, 50 – 60 Hz, 1 Amp
Important
: Reliable earthing must be maintained to ensure proper grounding for the SE
encoder. To ensure that circuits are not overloaded, read the encoder’s UL power label.
If the SE encoder is connected to a power strip, rather than a branch circuit’s direct
connection, use special care to ensure that the unit is properly connected.