CHAPTER 2 INSTALLATION
Introduction
This chapter provides information for mounting and installing the SE4750, including physical and electrical
considerations, and recommended window properties for the SE4750.
General Information
Default Power Mode
The default power mode for the SE4750 when connected to a PL3300 decoder is Bus-Powered USB Mode
(<500mA). VCC_ILLUM must be 5V when in this mode to achieve expected illumination brightness.
If operating in Self-Powered USB Mode (>500mA) or RS-232 Mode with VCC_ILLUM =3.3V, configure the PL3300
for one of these modes using config 0 and config 1 signals in order to achieve expected illumination brightness.
IMPORTANT
Mixing Bus-Powered USB Mode with VCC_ILLUM =3.3V does not achieve the expected illumination brightness.
This results in decode performance degradation and should be avoided.
Grounding
The chassis is at ground. Isolate the SE4750 and host if installing the engine to a host that is not at ground, or has
ground with the potential to inject noise.
CAUTION
When handling engines, do not touch the imaging lens. Properly protect fingers to prevent prints on
this lens.
CAUTION
Use care not to touch the Illumination LEDs during handling. Improper handling can damage the LED
lenses.
Summary of Contents for SE4750
Page 1: ...SE4750 INTEGRATION GUIDE ...
Page 2: ......
Page 3: ...SE4750 INTEGRATION GUIDE 72E 171726 01 Revision A November 2013 ...
Page 6: ...iv SE4750 Integration Guide ...
Page 10: ...viii SE4750 Integration Guide ...
Page 14: ...xii SE4750 Integration Guide ...
Page 18: ...1 4 SE4750 Integration Guide ...
Page 29: ...Installation 2 11 Aiming Pattern Figure 2 6 SE4750 SR LSR AIM Optical Path Aiming Pattern ...
Page 36: ...2 18 SE4750 Integration Guide ...
Page 53: ...Electrical Interface 4 5 Figure 4 3 Parallel Host Flex p n 15 171522 xx ...
Page 66: ...5 12 SE4750 Integration Guide ...
Page 78: ...A 2 SE4750 Integration Guide ...
Page 82: ...Index 4 SE4750 Integration Guide ...
Page 84: ......
Page 85: ......