Amplifier
Setup
3-5
PRELIMINARY - Motorola Internal Use Only
SLE*-* Installation and Operation Manual
STARLINE Cable Simulators
STARLINE cable simulators, model SCS-*, are used in place of fixed equalizers in systems
where: (1) the amplifiers are located close together, (2) there are large amounts of flat loss from
passive components, or (3) it is necessary to compensate for reverse cable tilt. The simulators fit
in the same location as the equalizers.
Table 3-2 and Figure 3-2 help you choose the correct simulators:
Table 3-2
STARLINE cable simulators
SCS-*
1 2 3 4 5 6 7 8 9 10
Frequency
Cable slope in dB
40 MHz
0.0 0.1 0.1 0.1 0.2 0.2 0.3 0.3 0.3 0.4
45 MHz
0.0 0.0 0.1 0.1 0.1 0.1 0.1 0.1 0.2 0.2
50 MHz
0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0
72 MHz
-0.1 -0.2 -0.2 -0.3 -0.4 -0.4 -0.5 -0.6 -0.7 -0.7
108 MHz
-0.1 -0.3 -0.4 -0.5 -0.6 -0.8 -0.9 -1.0 -1.2 -1.3
150 MHz
-0.2 -0.5 -0.7 -0.9 -1.2 -1.4 -1.6 -1.9 -2.1 -2.3
211 MHz
-0.3 -0.7 -1.0 -1.4 -1.7 -2.1 -2.4 -2.8 -3.1 -3.5
250 MHz
-0.4 -0.8 -1.2 -1.7 -2.1 -2.5 -2.9 -3.3 -3.7 -4.1
300 MHz
-0.5 -1.0 -1.5 -1.9 -2.4 -2.9 -3.4 -3.9 -4.4 -4.9
350 MHz
-0.6 -1.1 -1.7 -2.2 -2.8 -3.3 -3.9 -4.4 -5.0 -5.5
400 MHz
-0.6 -1.2 -1.8 -2.5 -3.1 -3.7 -4.3 -4.9 -5.5 -6.2
450 MHz
-0.7 -1.4 -2.0 -2.7 -3.4 -4.1 -4.7 -5.4 -6.1 -6.8
550 MHz
-0.8 -1.6 -2.4 -3.2 -4.0 -4.8 -5.5 -6.3 -7.1 -7.9
750 MHz
-1.0 -2.0 -3.0 -4.0 -5.0 -6.0 -7.0 -8.0 -9.0 -10.0
870 MHz
-1.1 -2.2 -3.3 -4.4 -5.5 -6.7 -7.8 -8.9 -10.0
-11.1
50 MHz loss (typical)
-1.0 -1.0 -1.0 -1.0 -1.0 -1.0 -1.0 -1.0 -1.0 -1.0