SSI Interface
4 - 7
Host Serial Response Time-out
Parameter # 9Bh
This parameter specifies how long the digital scanner waits for an ACK or NAK before resending. Also, if the digital
scanner wants to send, and the host was already granted permission to send, the digital scanner waits for the
designated time-out before declaring an error.
To set the delay period (options are 2, 5, 7.5, or 9.9 seconds), scan one of the following bar codes.
NOTE
Other values are available via SSI command
.
*
Low - 2 Seconds
(14h)
Medium - 5 Seconds
(32h)
High - 7.5 Seconds
(4Bh)
Maximum - 9.9 Seconds
(63h)