background image

-4

6880906Z38-O

November, 1999

Telario TS3000 Control Station Installation Manual

Time of Sale, End User Contract: All Zones

As a Dealer, it is your responsibility to inform the customer about UTAM, its
rules and regulations. This requirement applies to all zones.

The following

agreement must be included in your sales contract with your customer:

[Customer] hereby acknowledges that the use and operation of any intentional
radiator equipment requiring a Part 15.311 FCC label and subject to UTAM
clearing fees, the operation of which makes use of any part of the unlicensed
personal communications services (“UPCS”) frequency spectrum (“UPCS
Radiating Part”), is subject to FCC rules and regulations and UTAM require-
ments and instructions including without limitation rules, regulations,
requirements and instructions with respect to interference to licensed fixed
microwave facilities and to the relocation of any such UPCS Radiating Part.

[Customer] agrees that [its] use or operation of any UPCS Radiating Part shall
comply with all such rules, regulations, requirements and instructions.

Name Of Subscriber:            __________________________

State Of Incorporation:        __________________________

By: ___________________________

Name: _________________________

Title: __________________________

Address: _______________________

Date: __________________

Time of Installation, Product Registration & LVP: All Zones

To monitor deployment and power levels, all equipment sales must be regis-
tered with Motorola Product Services group at the time of installation. Infor-
mation is forwarded to UTAM, per its regulations. This procedure, required
for all zones, ensures that the band remains coordinated and operational for all
authorized vendors and their customers.

The registration form requires the following information:

- Customer name

- Site address

- City, state, zip and county name

- Site coordinates (latitude and longitude)

- UTAM PFC approval number (if the location is a Zone 2 or Zone 3 site)

- Quantity of Control Stations to be installed

- Quantity of handsets to be installed

- Installation date

- Maximum height of installation

Summary of Contents for Telario TS3000

Page 1: ...r is called In most but not all areas the sum of the RENs of all devices con nected to one line should not exceed five 5 0 To be certain of the number of devices you many connect to your line as determined by the REN you should contact your local telephone company to determine the maximum REN for your calling area If your telephone equipment causes harm to the telephone network the tele phone serv...

Page 2: ... telephone jacks in wet locations unless the jack is specifically designed for wet locations Never touch uninsulated telephone wires or terminals unless the tele phone line has been disconnected at the network interface Use caution when installing or modifying telephone lines UTAM What is UTAM UTAM Unlicensed Transition Management for Microwave Location is an organization which is composed of 15 c...

Page 3: ...on being less than 5 000 it has not been sched uled for conversion at this time Most Unclassified counties will be automatically converted to Zone 1 Status by UTAM when a member initiates a site specific coordination request with conversion costs to be paid by UTAM Overall Process Dealer contacts Motorola Product Srvcs to conduct site specific interference analysis frequency coordination ...

Page 4: ...agrees that its use or operation of any UPCS Radiating Part shall comply with all such rules regulations requirements and instructions Name Of Subscriber __________________________ State Of Incorporation __________________________ By ___________________________ Name _________________________ Title __________________________ Address _______________________ Date __________________ Time of Installati...

Page 5: ...dware serial number and authorization key assures that the Location Verification Process LVP is specific to each unique system each time the LVP is used The Motorola Product Services Group submits applica tion and registration information to UTAM on a weekly basis This informa tion will also be kept on the database at Motorola LVP is applicable for two main cases 1 Initial site installation Units ...

Page 6: ...bile Telecommunications Equipment M T E in the Frequency Range 30 MHz 6 GHz E M F Electromagnetic Fields Electromagnetic Interference Compatibility NOTE Nearly every electronic device is susceptible to electromagnetic interference EMI if inadequately shielded designed or other wise configured for electromagnetic compatibility To avoid electromagnetic interference and or compatibility conflicts tur...

Page 7: ...trol Station and may violate UTAM regulations Use only the Motorola approved antenna or antenna board General Control Station Care Your Control Station is made and tested to meet exacting safety standards It meets both UL and FCC requirements WARNING To reduce the risk of fire or electric shock do not expose the Con trol Station to rain or moisture Careful attention is devoted to quality standards...

Page 8: ...on the Control Station Servicing In each or any of the following conditions contact qualified per sonnel or your authorized Motorola dealer immediately When the power supply cord or plug is damaged If liquid has been spilled or objects have fallen into the Control Station or the power supply If the Control Station or the power supply has been exposed to rain or water If the Control Station does no...

Page 9: ...80906Z38 O 9 Telario TS3000 Control Station Installation Manual System Components Telario TS3000 Control Station Telario TC3000 Communicator Telario TR3000 Radio TS3000 Control Station TR3000 Radio TC3000 Communicator ...

Page 10: ...80427B06 Line Cord Part Number 3085714L01 Installation Manual Part Number 6880906Z38 Control Station Profile LED Definitions Control Connector Panels Green Indicates the Control Station is powered Amber Indicates phone operation is in progress Red System malfunction Attention needed 1 Phone Line 4 Phone Line Model Model Phone Lines Audio In Out Programming Remote Mount Antenna ...

Page 11: ...o answer to assist in system con figuration preparation How many work groups are required Who will be in each work group Who needs telephone capability and with what restrictions Who needs just a radio What if any accessories will be needed How many TC3000 Communicators and TR3000 Radios are needed Pre Installation Site Survey A pre installation site survey is critical to the success of the Telari...

Page 12: ...eight of the equipment Our standard mounting components can support 25 or more pounds If you substitute any components they too must support at least 25 pounds UL1950 also focuses on the physical installation and fire safety of the equip ment while Article 725 focuses on the power cabling We fall under Article 725 because we use a Class 2 power supply A Class 2 power supply must be UL listed must ...

Page 13: ... an analog PBX is being used be sure the PBX has lines available for each telephone line and or Communicator used in the Telario System Your customer may need to have the PBX manufacturer install additional line cards When an analog PBX is used some of its features may be passed through the Telario System to the handsets Others may not The Telario System can also work with digital PBX equipment in...

Page 14: ...led as well as expected system usage or loading Refer to Table 0 1 below for guidelines Be sure to consider future system requirements or upgrades Backup Power As a final activity in your pre sale work with the customer discuss battery backup If the Telario System is used for critical business communications you ll want to discuss whether backup power is available at the site or if the Motorola Ba...

Page 15: ...wer connector kit Wrenches screwdrivers Programming The final step to installation preparation is programming the customer s equipment with the Telario Management Tool TMT Refer to the TMT help windows for assistance Control Station Installation Mounting Ideal mounting choices are the bottom of a horizontal I beam or on the ceiling with the standard trunnion The trunnion allows at least 10 degrees...

Page 16: ...system design in the future you may want to consider adding the Control Station programming cable for reprogramming needs All cabling must comply with the National Electric Code NEC as well as the state city county and local building and fire code requirements You can use EIA TIA 568 as a beginning point UTAM Registration Mobility Feature UTAM requires that every installed Telario System is regist...

Page 17: ...ard in four line models These are accessible simply by removing the housing cover of the Control Sta tion To enable the adjustment capability the appropriate slide switch lever is moved toward the corresponding adjustment potentiometer Then initiate a phone call from another telephone to the Control Station Using a Communi cator to answer the call adjust the potentiometer with a small screwdriver ...

Page 18: ... 18 6880906Z38 O November 1999 Telario TS3000 Control Station Installation Manual ...

Reviews: