B - 2
XR Series RFID Readers Integrator Guide
Response.txt
FlashUpdateUtility.dll
XR4xxc42RCfgH001.hex
XR4xxc42RDatH001.hex
XR4xxc42OsH0XXXXXX.bin (OS, last 6 digits in the filename could change)
XR4xxc42MonHXXXXXX.bin (Monitor, last 6 digits in the filename could change)
XR4xxc42PlatHXXX.hex (
Platform
partition, last 3 digits in the filename could change)
XR4xxc42AppHXXX.hex (Application, last 3 digits in the filename could change)
XR4xxc42Ptbl64HXXX.hex (Partition table, last 3 characters in the filename could change)
XR4xxc42BootHXXX.hex (Boot, last 3 characters in the filename could change)
XR4xxc42Data64HXXX.hex (
Data
partition, last 3 characters in the filename could change)
XR4xxc42RCfgHXXX.hex (Reader Config, last 3 characters in the filename could change)
XR4xxc42RDatHXXX.hex (Reader Data, last 3 characters in the filename could change).
Not all of the files are updated every release. Read the release notes for information about which files were
changed. Unlike the AR400 upgrade, there is not a specific order necessary when installing these files. Determine
which files need to be updated.
Auto Recovery
The Auto Recovery feature allows the reader to recover flash images that have been corrupted due to a power
outage during a software upgrade. Two images of the Monitor are maintained, and the bootstrap code determines
the correct version to use. The Monitor then determines if a software upgrade was interrupted and if so, downloads
the partitions again.
Update Phases
The firmware update takes place in two phases:
Phase 1:
The reader application retrieves the
Response.txt, osupdxr400.exe
, and
FlashUpdateUtility.dll
files from the ftp server.
Phase 2:
The reader application is shut down and the
OsUpdate
starts. The files referenced in the
Response.txt
file are retrieved from
the ftp server.
A typical entry in the Response.txt file looks like:
;
Platform
partition version 1.2.7
-t4 -fXR4xxc42PlatH127.hex -s2679149
The -t parameter is the file type, -f is the name of the file, and -s the size. Please ensure that the file size is correct.
A ";" comments out the rest of the line.
NOTE
The DSP Loader, DSP code, Application Server and FPGA code are all in the
Platform
partition.
Summary of Contents for XR400
Page 1: ...XR Series RFID Readers Integrator Guide ...
Page 2: ......
Page 3: ...XR Series RFID Readers Integrator Guide 72E 71773 08 Rev A December 2008 ...
Page 6: ...iv XR Series RFID Readers Integrator Guide ...
Page 14: ...xii XR Series RFID Readers Integrator Guide ...
Page 74: ...3 46 XR Series RFID Readers Integrator Guide ...
Page 86: ...4 12 XR Series RFID Readers Integrator Guide ...
Page 95: ...Security 5 9 Figure 5 12 Connection Using PuTTY Client Window ...
Page 106: ...5 20 XR Series RFID Readers Integrator Guide ...
Page 110: ...A 4 XR Series RFID Readers Integrator Guide ...
Page 124: ...Index 4 XR Series RFID Readers Integrator Guide ...
Page 125: ......