Gas (Petrol) Service
Vehicle Connection Procedure (General)
1. For best results ensure vehicle is at operating temperature before performing a service.
2. Turn vehicle off.
3. Fill on board tank with mixed Gas (Petrol) see pg 8 for details.
4. Turn the Gasoline (Petrol) PRESSURE REGULATOR counterclockwise until the regulator is completely
open. Verify that the ON/OFF switch is turned off.
5. Attach the unit to the vehicle’s battery by connecting the red battery clip to the positive battery terminal
and the black battery clip to a solid ground point on the chassis.
6. Press the service selector to the Gas (Petrol) side.
7. Remove the vehicle’s gas cap to relieve tank pressure.
8. Connect the Carbon Clean Dual to the vehicle using appropriate adapters.
9. Go to next service procedure step based on connection method
info@motorvac.com www.motorvac.com
9
WARNING
Flammable Liquid can squirt out of pressurized lines when connecting or disconnecting.
Verify that engine and machine are both off before connecting or disconnecting fuel
lines or adapters.
Wear safety goggles.
Wear chemical resistant gloves when connecting or disconnecting fittings and adapters.
Wrap a shop towel around pressure fittings and adapters when disconnecting.
Avoid exposure to flames, sparks, hot engine parts, and other ignition sources.
Explosion or flame or exposure to flammable liquid and vapors can cause injury.