info@motorvac.com www.motorvac.com
TransTech IV+ Auto-Prime Procedure
(For first time set-up only)
Set-Up Instructions:
1. Check the output/return hoses, battery connections, and all external components for damage.
2. Fill the
CLEAN FLUID
tank with approximately 6 quarts (5.7 liters) of new ATF.
3. Connect two compatible adapters to each other, secure tightly. Attach the
CLEAN FLUID & INLINE
RETURN
hoses together using the connected adapters
4. Place the waste hose into the clean tank fill neck with the ball valve open.
5. Attach the units’ red (+) battery clip to vehicle’s positive battery terminal; connect the black (-) battery clip
to a solid ground point as far from the battery as possible.
6. Check to ensure the unit is in Inline mode (Inline LED is on). Press and hold the START button for 5
seconds until the unit sounds the alarm. The FILL and DRAIN LEDs will flash. Press and hold the
START button again for 5 seconds until the unit sounds the alarm. The DRAIN, FILL and COMPLETE
LEDs will cycle in a clockwise direction while the unit is performing the Auto-Prime procedure. The unit
will pump fluid from the clean tank to the waste tank. The unit will then set the waste tank zero level by
pumping fluid from the waste tank into the clean tank. When complete, the unit will automatically reset.
7. Return the hoses to their original location.
8. The initial setup is complete.
6