Troubleshooting and Additional Help
Refer to the list below in the unlikely event that you have problems with your
SteerClean-II Power Steering
Service System
.
Problem:
Solution:
1. Unit does not power-up, no LEDs
are lighted
-
Inspect power cord for breaks
-
Reset Circuit Breaker
-Verify 12 volts available from battery.
2. Vehicle reservoir is overflowing
Check the ‘cleanable’ screen filter inside the back
cover for blockage. “Wand” suction hose may be
blocked with debris.
3. The Waste Tank pump is running,
but nothing is coming out of the
waste hose.
-The waste tank has a filter in-line between the pump
and the waste tank. To access, remove the front
“lower” metal cover. The filter and pump are located
in the space below the waste capture tank. Clamp the
hose closed between filter and tank. Push together and
twist the two halves of the filter in opposite directions
and separate. Remove screen with sharp pointed probe
to clean. Reassemble. Align slots and push and twist
filter closed. Be careful not to pinch the o’ring.
Remove clamp and check for leaks.
ADDITIONAL HELP
Please verify that items above have been reviewed
before calling for additional assistance.
In the unlikely event that problems persist with the unit
call
Technical Support, have your model and serial numbers
available before you call. Remember to send in your
warranty card.
In the U.S. Canada:
(800)
841-8810
Contact
your
local
Summary of Contents for SteerClean-II 500-7100
Page 2: ...Manual 100 7100 ii...
Page 4: ...Manual 100 7100 iv Notes...
Page 6: ...Manual 100 7100 vi Notes...
Page 8: ...Manual 100 7100 8 Notes...
Page 18: ...Manual 100 7100 18 Notes...
Page 22: ...Manual 100 7100 22 Notes...
Page 26: ...Manual 100 7100 26 714 558 4822 MotorVac distirbutor...
Page 27: ...Manual 100 7100 27...
Page 33: ...Manual 100 7100 33 Standard Adapters...
Page 37: ...Manual 100 7100 37...