Appendix A - Maintenance
Maintenance Procedures
The following maintenance procedures should be performed on a routine
basis:
1.
Carefully clean the exterior with a soft cloth to keep the cabinet
looking new. Check the cabinet for dents or impact markings, if
found, inspect for damaged components
.
2.
Check all hoses and wires for cuts or frays.
3.
Clean the unit’s waste filter screen after every 100 services or
6 months, which ever comes first. See the next section for procedure.
Cleaning The Unit’s Filter
1.
Disconnect power harness from any power source.
2.
Place unit on suitable catch tray.
3.
Remove the lower front ‘metal” cover to expose the filter on bottom
‘waste fluid tank. Remove the back cover to access the Suction line
filter.
4.
Hold the bottom (black) half of the filters while rotating the other
(clear) half of the filters
counter-clockwise
. Then separate the two
pieces by pulling apart.