background image

17

Model EA91A&EA90A

KXB-LO-16

(Standard)

Basic Shape of 

Rubber Packing

KXB-LO-16F

(Special Specifications)

1

3

5

1

2

.5

1

5

3

.5

3

1

⑹ Tighten union coupling and union cover.

Unit : mm

Nominal Size

of Packing

Outer Diameter

of Cable

Inside Diameter

of Packing

         ∅d

10

11

10

11

∅9.1〜

10

∅10.1〜

11

2

0

D

Terminal Cover

Shrouding Screw

Special O Ring

O Ring

O Ring

Hexagon Socket Head Set Screw

Clamp

Cable Gland

Union Cover

Union Coupling with Set Screw

Left Side(+)

Right Side(−)

Lock Nut

Connecting Body

Rubber Packing

Washer

W

A

R

N

IN

G

For connector of flameproof packing type, use 
the following two connectors certified at the 
same time of EA91A and EA91AC.
   ① KXB-LO-16 (Standard) 
   ② KXB-LO-16F 
     (Specified, Special Specifications) 
※Impossible to use connector other than two   
   connectors described above.

※The cable to be connected shall be equal  

   to or better than vinyl insulated vinyl sheath 

cable for control "CVV" (JIS C3401).

⑴ Process end of cable using crimp-style      
  terminal. Refer to the table shown below  
  for outside diameter of cable.
⑵ Screw-in connecting assembly to ter-
  minal box, and fix with lock nut.

⑶ Insert  cable  gland,  union  coupling,  and 

union cover to the cable.

⑷ Then, insert washer and rubber packing to 

the cable, screw-in cable gland securely, and 
lock the hexagon socket head set screw to 
tighten clamp.

⑸ Two types of the rubber packing for cable 

are included.

5.3.1.2 Leading Procedure for Flameproof 
   Packing Type (Optional Specifications) 

⑴ Loosen the shrouding screw (M3 Hexagon 

Socket Set Screw), and remove terminal cover. 

⑵ Connect cable to terminal block. 
   Terminal Screw Size : M4 
   Standard Wiring (Positioner Wiring) 
   Right Terminal (−) (Black Colored Lead Wire) 
   Left Terminal (+) (Red Colored Lead Wire) 
   Reverse Positioner (Model EA90A is not applicable) 
   Right Terminal (Red Colored Lead Wire) 
   Left Terminal (Black Colored Lead Wire) 
   Even if connecting reverse positioner, perform 

wiring  in  accordance  with  the  indication  of 
terminal. (Wiring has been converted and ad-

   justed to reverse positioner by MOTOYAMA.) 
⑶ After completing connection, screw-in the 

shrouding screw to terminal cover, and lock 
the shrouding screw.

5.3.1.3 Connecting Procedure

Ground

Cross Recessed Head and Pan Head Screw

Summary of Contents for EA90A

Page 1: ...purpose only and should not be considered certi ed marketability and conformability of this product MOTOYAMA is continuously improving and upqrading its product design speci cations and or dimensions...

Page 2: ...roduct without notice the speci cations dimensions adjustments illustrations and other items included in this manual might be di erent in details For any questions about the delivered product or this...

Page 3: ...tuator 4 6 Conformity of Capacity and Characteristics 4 7 Installing Dimensions 2 2 2 3 4 4 4 4 5 5 5 6 7 8 8 9 9 10 11 12 14 15 15 16 16 19 19 20 20 20 20 20 22 22 23 23 24 25 26 26 27 5 EXTERNAL CON...

Page 4: ...ther the explosive gases are absent or not maintenance must be limited to visual inspection and adjustment of movable parts not requiring the opening of the terminal box such as zero adjustment and st...

Page 5: ...tenance the EA90A Valve Positioner installed in hazardous area carefully make sure before and during maintenance whether the explosive gases are absent or not by using gas detector 2 Maintenance durin...

Page 6: ...valve positioners are of explosion protected construction and are improved the positioning accuracy and response performance of process control valves installed in hazardous areas 2 2 Applicable Regu...

Page 7: ...tioner case 2 The explosion protection WARNING nameplate is attached on the upper part of terminal box EA91A and EA90A have di erent contents each other 3 The speci cation nameplate is attached on the...

Page 8: ...r the safety barrier selection please refer to the following data for Intrinsically safe approval of model EA90A Performance classi cation and Group ia II C Permissible maximum values Ui 30V Ii 100mA...

Page 9: ...s from the controller into pneumatic pressure to position the opening of pneumatic control valve As the signal current from the controller or manual operator increases the torque motor coil generates...

Page 10: ...58 5 164 5 51 7 45 5 137 218 KXB LO 16F Special Option KXB LO 16 Standard 3 51 51 135 12 5 153 5 31 7 Left Lateral View Built in Cam Type See above as left lateral view Leading External Cable Conduit...

Page 11: ...dered speci cation is conformed with 2 Appearance Check Check the presence of damage on the device due to transport 3 Accessory Identi cation Lever Type Bracket Stem Clamp Connector Arm included Feedb...

Page 12: ...tion Fix the connector pin to feedback lever and connector arm IMPORTANT IMPORTANT At this point attach the stem clamp upward approx 5 to 10 mm from lock nut Fix the connector arm so as to be parallel...

Page 13: ...o connecting shaft Attach the bracket Attach the bracket to the preinstalled spacer bolt Attach the connecting pipe Attach the connecting pipe to the serrated portion of the feedback shaft at back sid...

Page 14: ...ce plate with cut position of gasket When replacing or changing the position of ori ce plate remove pilot cover and loosen three screws xing pilot assembly General classi cation for usage of ori ce pl...

Page 15: ...amped on the cam Loosen ange nut to select cam or to adjust position of cam 4 6 2 Selection of Buit in Cam The exhaust hole of pilot cover changes due to installation position of the positioner Refer...

Page 16: ...100 45 45 45 58 185 185 185 195 215 225 233 312 A B C D L Unit mm Actuator Size 240 280 330 400 500 650S 241 241 241 241 125 125 185 185 93 93 143 143 193 205 223 296 250 270 305 405 A B C D L Unit m...

Page 17: ...afety Construction Supply Pressure Supply Pressure Electro controller Electro controller Hazardous Area Non hazardous Area Hazardous Area Non hazardous Area Safety Barrier Air Filter Regulator Air Fil...

Page 18: ...pneumatic Valve Positioner Flameproof Explosion protected Construction Connect wires in accordance with the wiring diagram in Item 5 1 1 The parallel pipe female thread G1 2 PF1 2 female screw is used...

Page 19: ...for outside diameter of cable Screw in connecting assembly to ter minal box and x with lock nut Insert cable gland union coupling and union cover to the cable Then insert washer and rubber packing to...

Page 20: ...the wires against external damages Be sure to ground uncharged open metallic parts Connect wires in accordance with the wiring diagram shown in Item 5 1 2 The parallel pipe female thread G1 2 PF1 2 f...

Page 21: ...ossible to inspect and adjust with the cover removed However be very careful not to generate impact sparks during maintenance 6 1 Advance Check before Calibration Switching of Direct Reverse Action fo...

Page 22: ...tment Common to Linear Type and Built in Cam Type Loosen lock screw xing stroke adjustment knob of the stroke adjustment lever If making the stroke angle wider adjust by turning screw of stroke adjust...

Page 23: ...Actuator Type 3900 Standard Cam for Linear Special Cam for Eq Kinds of Spring Feedback Spring Identification Color None Blue None Blue Black White Red Yellow Standard 1 2 Standard 1 2 Zero Adjustment...

Page 24: ...ck at the back of the terminal cover IMPORTANT Never remove the stopper screw IMPORTANT If not venting through the ltered regulator it might apply excessive pneumatic pressure to the positioner or the...

Page 25: ...bsence of wear and tear Use Plasti lube 00 when reassembling Pressure Gauge Restriction Fixed Restriction Filter Diaphragm Gasket Packing Nozzle Flapper Supply Air Valve Seat for Main Body Feedback Le...

Page 26: ...f the pilot cover with original position and mount the pilot cover 7 2 2 Pilot Follow the procedure described in Item 7 2 1 for operation of supply air pressure and ltered pressure reducing valve For...

Page 27: ...al switching mechanism to M adjust supply air pressure and check whether control valve works normally or not If abnormality is present disassemble control valve Remove short circuited part and then ch...

Page 28: ...k Spring Main Body Pilot Valve Output Pressure Gauge Manual Switching Screw Zero Adjustment Knob Terminal Box Zero Adjustment Spring Nozzle Flapper Model EA91A EA90A Electro pneumatic Valve Positioner...

Page 29: ...5 10 12 7 2800 3800 3400 2800 3800 2800 2800 3800 3300 9 2 Dimension of Fitting Bracket Note 1 Actuator Type The bracket for 3800 3400 and 3300 can be attached to Model EA91A electro pneumatic valve...

Page 30: ...293 183 293 191 298 80 80 110 100 110 100 110 100 52 52 70 80 110 90 130 140 240 330 240 330 400 500S 500 500SH BL 500SH BL 650 650 Actuator Size Actuator Type L 40 55 240 280 N24 N40 200 270 C20 330...

Page 31: ...450 792 0851 1013 1 TEL 0897 40 0270 FAX 0897 40 0305 870 0108 980 1 TEL 097 527 3704 FAX 097 522 2352 116601 39 14 7 TEL 86 411 6589 1277 FAX 86 411 6589 1278 SALES AND SERVICE NETWORK Overseas Marke...

Reviews: