17
Model EA91A&EA90A
KXB-LO-16
(Standard)
Basic Shape of
Rubber Packing
KXB-LO-16F
(Special Specifications)
1
3
5
1
2
.5
1
5
3
.5
3
1
⑹ Tighten union coupling and union cover.
Unit : mm
Nominal Size
of Packing
Outer Diameter
of Cable
Inside Diameter
of Packing
∅d
10
11
∅
10
∅
11
∅9.1〜
10
∅10.1〜
11
∅
2
0
∅
D
Terminal Cover
Shrouding Screw
Special O Ring
O Ring
O Ring
Hexagon Socket Head Set Screw
Clamp
Cable Gland
Union Cover
Union Coupling with Set Screw
Left Side(+)
Right Side(−)
Lock Nut
Connecting Body
Rubber Packing
Washer
W
A
R
N
IN
G
For connector of flameproof packing type, use
the following two connectors certified at the
same time of EA91A and EA91AC.
① KXB-LO-16 (Standard)
② KXB-LO-16F
(Specified, Special Specifications)
※Impossible to use connector other than two
connectors described above.
※The cable to be connected shall be equal
to or better than vinyl insulated vinyl sheath
cable for control "CVV" (JIS C3401).
⑴ Process end of cable using crimp-style
terminal. Refer to the table shown below
for outside diameter of cable.
⑵ Screw-in connecting assembly to ter-
minal box, and fix with lock nut.
⑶ Insert cable gland, union coupling, and
union cover to the cable.
⑷ Then, insert washer and rubber packing to
the cable, screw-in cable gland securely, and
lock the hexagon socket head set screw to
tighten clamp.
⑸ Two types of the rubber packing for cable
are included.
5.3.1.2 Leading Procedure for Flameproof
Packing Type (Optional Specifications)
⑴ Loosen the shrouding screw (M3 Hexagon
Socket Set Screw), and remove terminal cover.
⑵ Connect cable to terminal block.
Terminal Screw Size : M4
Standard Wiring (Positioner Wiring)
Right Terminal (−) (Black Colored Lead Wire)
Left Terminal (+) (Red Colored Lead Wire)
Reverse Positioner (Model EA90A is not applicable)
Right Terminal (Red Colored Lead Wire)
Left Terminal (Black Colored Lead Wire)
Even if connecting reverse positioner, perform
wiring in accordance with the indication of
terminal. (Wiring has been converted and ad-
justed to reverse positioner by MOTOYAMA.)
⑶ After completing connection, screw-in the
shrouding screw to terminal cover, and lock
the shrouding screw.
5.3.1.3 Connecting Procedure
Ground
Cross Recessed Head and Pan Head Screw