background image

Dx350_06d_oi_e.docx / Jul-20 

 

 

page 2 / 67 

Die deutsche Beschreibung ist verfügbar unter: 

https://www.motrona.com/fileadmin/files/bedienungsanleitungen/Dx350_d.pdf 

 

The English description is available at: 

https://www.motrona.com/fileadmin/files/bedienungsanleitungen/Dx350_e.pdf 

 

La description en français est disponible sur: 

https://www.motrona.com/fileadmin/files/bedienungsanleitungen/Dx350_f.pdf 

 

The operator software OS 6.0 (freeware) is available at: 

https://www.motrona.com/en/support/software.html

 

 

 

Version: 

Description 

DX350_01a_oi/sn- tg /Jul-20 

First Version 

DX350_01d_oi/cn/Okt-16 

Revised first Version 

DX350_02a_oi/cn/Nov-16 

Second Version 

DX350_02c_oi/cn/Jan-17 

Revised Version 

DX350_03a_oi/cn/Apr-17 

Revised Version 

DX350_03b_oi/cn/Jun-17 

Other small changes 

DX350_04a_oi/cn/Sep-17 

Extension DX355, software customization 

DX350_05a_oi/cn/April-18 

Extension of serial interface with Modbus protocol 

DX350_05b_oi/cn/June-18 

Addendum to Modbus et accuracy 

DX350_05c_oi/cn/July-18 

With Modbus description 

DX350_06a_oi/tgo/Mar-19 

Extension of large display, total counter and total time measurement

 

DX350_06b_oi/mbo/Aug-19 

Extension of QR-code 

DX350_06c_oi/tgo/Nov-19 

Extension of the “Preselection Mode” and “Input Action” 

DX350_06d_oi/mbo/July-20 

Extension of chapter 1.4 “EMC Guidelines”, various revisions 

 
 

Summary of Contents for DX350

Page 1: ...lay inclusively icons and units Intuitive and easy parameterization by plain text and touchscreen 5 24 V auxiliary output for encoder supply Input frequencies up to 1 MHz Linearization with 24 interpo...

Page 2: ...on DX350_01d_oi cn Okt 16 Revised first Version DX350_02a_oi cn Nov 16 Second Version DX350_02c_oi cn Jan 17 Revised Version DX350_03a_oi cn Apr 17 Revised Version DX350_03b_oi cn Jun 17 Other small c...

Page 3: ...ts included in this manual are protected by the terms of use and copyrights of motrona GmbH Any reproduction modification usage or publication in other electronic and printed media as well as in the i...

Page 4: ...nterface Option AO AR CO CR 15 Control Output AO AR CO CR 15 AC Power supply Option AC 16 Relay Output Option RL 16 Display and touch screen 17 Screen structure for parametrization 17 Screen structure...

Page 5: ...Dx350_06d_oi_e docx Jul 20 page 5 67 Diagnostics 57 Parameter serial codes 58 Linearization 63 Dimensions 65 Technical specifications 66...

Page 6: ...rves the right to modify the hardware software or operation manual at any time and without prior notice Therefore there might be minor differences between the unit and the descriptions in operation ma...

Page 7: ...further indicated as separator Incoming as well as outgoing wires and wires for extra low voltages ELV must be separated from dangerous electrical cables SELV circuits by using a double resp increased...

Page 8: ...be mounted in a metal enclosure with sufficient distance to sources of electromagnetic noise Run signal and control cables apart from power lines and other cables emitting electromagnetic noise Please...

Page 9: ...of frequency RMP indicator Monitoring functions for speed and standstill PROCESS TIME only input A is used Processing time indicator reciprocal speed Baking time indicator Flow time indicator TIMER on...

Page 10: ...Dx350_06d_oi_e docx Jul 20 page 10 67 Function diagram...

Page 11: ...l GND terminals are internally interconnected Auxiliary Voltage Output Terminal 3 and 4 provide an auxiliary output for supply of sensors and encoders The output voltage depends on the power supply DC...

Page 12: ...PNP NPN Namur Tri State Unconnected PNP inputs are always LOW and unconnected NPN inputs are always HIGH All inputs are designed to receive impulses from electrical impulse sources Notice for mechani...

Page 13: ...2 signals The characteristics of the incremental input can be set in the GENERAL MENU Wiring of the incremental inputs RS422 HTL DIFFERENTIAL HTL PNP single ended HTL NPN single ended Unconnected PNP...

Page 14: ...ng contacts When exceptionally mechanical contacts are used please connect an external capacitor between GND and the corresponding input A capacity of 10 F will reduce the input frequency to 20 Hz and...

Page 15: ...shows the connection to a PC by using a standard Sub D 9 connector Connection of the RS232 interface Connection of the RS485 interface Control Output AO AR CO CR Four control outputs are available at...

Page 16: ...age output Devices with option AC can also be supplied with a DC voltage between 18 and 30 VDC at terminals 1 and 2 Relay Output Option RL Two relay outputs with potential free changeover contacts are...

Page 17: ...ect the parameter menu via arrow buttons and confirm with OK The menu selection can be terminated with C Parameter selection Select the parameter via arrow buttons and confirm with OK The parameter se...

Page 18: ...top of the screen This is only possible in operation mode COUNTER A B A B or BATCH TOTAL MODE is active or in operation mode TIMER TOTAL TIME MODE is active Two line display with units To switch to t...

Page 19: ...ble with option AO CO RL Display with minimum and maximum value To switch to the next display press the top of the screen or the skip button Error messages ERROR MAXIMUM DISPLAY VALUE The display valu...

Page 20: ...is greater than 99 999 999 ERROR MIN DOWN DISPLAY VALUE Down display value of the two line display is less than 99 999 999 ERROR MAX LARGE DISPLAY VALUE The display value of the large display is grea...

Page 21: ...AL MODE ENCODER PROPERTIES ENCODER SUPPLY COUNTING DIRECTION SCALE UNITS SCALE UNITS BATCH LINEARIZATION MODE PIN PRESELECTION PIN PARAMETER BACK UP MEMORY FACTORY SETTINGS MODE SPEED DISPLAY VALUE BA...

Page 22: ...Y 3 OUTPUT LOCK 3 START UP DELAY 3 EVENT COLOR 3 PRESELECTION 4 MENU SOURCE 4 MODE 4 HYSTERESIS 4 PULSE TIME 4 OUTPUT TARGET 4 OUTPUT POLARITY 4 OUTPUT LOCK 4 START UP DELAY 4 EVENT COLOR 4 Menu Param...

Page 23: ...input for DX350 0 PNP PNP switch to 1 NPN NPN switch to 2 NAMUR Connect sensor to GND and sensor to input A or B 3 TRI STATE Tri State for push pull encoders sensors ENCODER PROPERTIES for DX355 This...

Page 24: ...NITS BATCH 0 Hz Default 1 kHz 2 m s 3 m min 4 km h 5 mph 6 1 min 7 RPM 8 1 sec 9 RPS 10 Stk h 11 pcs h 12 mm 13 m 14 inch 15 feet 16 Stueck 17 pcs 18 sec 19 min 20 Min Sec 21 H M S 22 Min Sec 00 23 l...

Page 25: ...N code to lock the quick start of the menu PRESELECTION VALUE for entering the preselection values Master PIN 6079 This Lock function is only useful in conjunction with active lock function in PIN PAR...

Page 26: ...value 100 Default value 500000 Highest value DECIMAL POINT This value defines the position of the decimal point 0 NO No decimal point 1 0000000 0 Decimal point at the specified position 2 000000 00 De...

Page 27: ...be set in PRESELECT MENU 0 00 Shortest time 99 99 Largest time AVERAGE FILTER Selectable average or filter function to avoid measuring fluctuations by unstable frequencies At setting 1 to 4 a floating...

Page 28: ...int will be set automatically 0 SECONDS Display in seconds 1 MINUTES Display in minutes 2 MIN SEC Display in minutes seconds 3 MIN 00 Anzeige in Minuten und 1 100 Minuten 4 H M S Anzeige in Stunden Mi...

Page 29: ...can be set in PRESELECT MENU 0 00 Shortest time 99 99 Longest time AVERAGE FILTER Selectable average or filter function to avoid measuring fluctuations by unstable frequencies At setting 1 to 4 a floa...

Page 30: ...me measurement 0 COUNT AT A HIGH Time measurement active at Input A is HIGH 1 COUNT AT A LOW Time measurement active at Input A is LOW 2 START A STOP B A rising edge at Input A starts the time measure...

Page 31: ...ime measurement runs parallel to the normal time measurement If the total time measurement should be automatically reset to O when 1 30 H M is reached the reference source must be set e g to SOURCE1 f...

Page 32: ...nting x4 FACTOR Scaling factor With the summing mode A B and the differential mode A B please note that the impulse scaling factor will only affect input A For example A setting of factor 1 23456 and...

Page 33: ...n or equal RESUL PRES Example for the total counter For the total counter BATCH TOTAL MODE must be set to TOTAL COUNTER The total counter counts here parallel to the main counter e g If the total coun...

Page 34: ...ling edge at Input A Stop rising edge at input B DISPLAY VALUE Desired value which should be displayed at the setting of BASE TIME S 1 Smallest value 1000 Default value 999999 Highest value BASE TIME...

Page 35: ...The display value is retained until a new value is determined 0 01 Frequency 0 Hz for frequencies below 100 Hz 99 99 Frequency 0 Hz for frequencies below 0 01 Hz STANDSTILL TIME This parameter define...

Page 36: ...999 Smallest value 1000 Default value 99999999 Highest value PRESELECTION 2 Preselection switching point 2 99999999 Smallest value 2000 Default value 99999999 Highest value PRESELECTION 3 Preselection...

Page 37: ...selected operating mode 1 COUNTER A Reference source is the counter reading of channel A only visible in mode COUNTER COUNT MODE A B or A B 2 COUNTER B Reference source is the counter reading of chann...

Page 38: ...ual PRESELECTION 1 e g underspeed start up suppression START UP DELAY is advisable With HYSTERESIS 1 not equal 0 the following switching condition is applied Display value PRESELECTION 1 ON Display va...

Page 39: ...No output pulse static signal 60 000 Pulse duration of 60 seconds OUTPUT TARGET 1 Assignment of an output or relay for the switching condition of preselection 1 If more than one switching condition is...

Page 40: ...art Up Delay 3 and 4 have an automatic start up suppression 00 000 No start up suppression 60 000 Start up suppression in seconds EVENT COLOR 1 Event depending change of the display color for the swit...

Page 41: ...N 1 MENU PULSE TIME 2 S Duration of output pulse for the switching condition of preselection 2 See chapter PRESELECTION 1 MENU OUTPUT TARGET 2 Assignment of an output or relay for the switching condit...

Page 42: ...TION 1 MENU OUTPUT TARGET 3 Assignment of an output or relay for the switching condition of preselection 3 See chapter PRESELECTION 1 MENU OUTPUT POLARITY 3 Polarity for the switching condition of pre...

Page 43: ...TION 1 MENU OUTPUT TARGET 4 Assignment of an output or relay for the switching condition of preselection 4 See chapter PRESELECTION 1 MENU OUTPUT POLARITY 4 Polarity for the switching condition of pre...

Page 44: ...it data format 0 7 EVEN 1 7 data Parity even 1 Stop 1 7 EVEN 2 7 data Parity even 2 Stops 2 7 ODD 1 7 data Parity odd 1 Stop 3 7 ODD 2 7 data Parity odd 2 Stops 4 7 NONE 1 7 data no Parity 1 Stop 5 7...

Page 45: ...on is stopped for 20 s 0 000 All cyclic transmission is switched off The unit will send data upon a serial request or with command SERIAL PRINT 60 000 Cycle time in seconds SERIAL VALUE This parameter...

Page 46: ...MODE YES ANALOG FORMAT This parameter defines the output characteristics The analogue output is proportional to the display value With setting ANALOG FORMAT 10 10 V in MODE COUNTER the polarity of the...

Page 47: ...67 Continuation Analog MENU ANALOG OFFSET This parameter defines the zero offset of the analog output z B 0 20 result in an offset of 0 02 V or 0 04 mA at ANALOG START value 99 99 Smallest offset 0 D...

Page 48: ...ELECTION 1 4 d 18 SET GREEN COLOR The display lights up green The color can be changed by the event dependent color switching in the PRESELECTION 1 4 d 19 SET YELLOW COLOR The display lights up yellow...

Page 49: ...DGE Activate at falling edge INPUT 2 ACTION This parameter defines the function of the input Ctrl In 2 See parameter INPUT 1 ACTION INPUT 2 CONFIG This parameter defines the switching characteristics...

Page 50: ...y second line 0 MEASUREM RESULT Reference source is the measurement result of the selected operating mode 1 COUNTER A Reference source is the counter reading of channel A only visible in mode COUNTER...

Page 51: ...e time FONT This parameter defines the setting of the font style 0 Standard 1 Font 1 START DISPLAY This parameter defines the start display after switching on device 0 STANDARD Display with unit and s...

Page 52: ...splay value for the large display can be divided Applies only for all 99999999 number formats 0 NO Large display off 1 1 1 Large display with splitting ratio 1 1 2 1 10 Large display with splitting ra...

Page 53: ...d examples are shown in the appendix P1 X P24 X X coordinate of the linearization point This value representing the display value which the unit show in the display without linearization 99999999 Smal...

Page 54: ...To request for a data transmission you must send the following request string to the converter EOT AD1 AD2 C1 C2 ENQ EOT control character Hex 04 AD1 unit address High Byte AD2 unit address Low Byte...

Page 55: ...ter setting Required parameter settings in DX350 DX355 Serial menu UNIT NUMMER Not valid for Modbus communication For setting of Modbus address see parameter MODBUS SERIAL BAUD RATE This parameter def...

Page 56: ...l variables actual data and status registers are mapped to Modbus Holding Registers However as all registers of the device are 32 bit registers but Modbus Holding registers are only 16 bit registers e...

Page 57: ...le to read and set reset single commands Coil number Serial code of command Command 0 54 Reset Set Reset Set Value 1 55 Freeze Display Freeze actual display value 2 56 Touch Disable Disable touch scre...

Page 58: ...0 0 0 21 MODE SPEED 21 0 0 0 22 MODE PROCESS TIME DISPLAY FORMAT 22 0 3 0 23 MODE PROCESS TIME DISPLAY VALUE 23 1 99999999 1000 24 MODE PROCESS TIME BASE FREQUENCY HZ 24 1 500000 100 25 MODE PROCESS...

Page 59: ...0 60000 0 70 PRESELECTION 1 MENU EVENT COLOR 1 C1 0 3 0 71 PRESELECTION 1 MENU C2 0 0 0 72 PRESELECTION 2 MENU SOURCE 2 C3 0 5 0 73 PRESELECTION 2 MENU MODE 2 C4 0 11 0 74 PRESELECTION 2 MENU HYSTERE...

Page 60: ...U G5 0 0 0 119 COMMAND MENU INPUT 1 ACTION G6 0 29 0 120 COMMAND MENU INPUT 1 CONFIG G7 0 3 2 121 COMMAND MENU INPUT 2 ACTION G8 0 29 0 122 COMMAND MENU INPUT 2 CONFIG G9 0 3 2 123 COMMAND MENU INPUT...

Page 61: ...1 99999999 99999999 0 165 LINEARIZATION MENU P13 Y L2 99999999 99999999 0 166 LINEARIZATION MENU P14 X L3 99999999 99999999 0 167 LINEARIZATION MENU P14 Y L4 99999999 99999999 0 168 LINEARIZATION MENU...

Page 62: ...e Command 54 RESET SET 55 FREEZE DISPLAY 56 TOUCH DISABLE 57 CLR LOCK 58 CLR MIN MAX 59 SERIAL PRINT 60 TEACH PRES 1 61 TEACH PRES 2 62 TEACH PRES 3 63 TEACH PRES 4 64 SCROLL_DISPLAY 65 CLEAR LOOP TIM...

Page 63: ...parameters P1 X to P24 X are used to specify the coordinates on the x axis These are the measuring values that the unit normally would generate according to the actual input signal Now enter the attac...

Page 64: ...ion Example The picture below shows a watergate where the opening is picked up by means of an incremental encoder We would like to display the clearance of the gate d but the existing encoder informat...

Page 65: ...Dx350_06d_oi_e docx Jul 20 page 65 67 Dimensions...

Page 66: ...nputs Number of inputs Configuration Format Frequency Load 2 A B PNP NPN Namur or Tri State HTL Low 0 3 V High 9 30 V max 250 kHz max 6 mA Ri 5 kOhm 470 pF Incremental inputs DX355 Number of inputs Co...

Page 67: ...it height Color Operation Graphic LCD with backlight 8 digits plus sign 99999999 99999999 13 mm height red green yellow selectable resistive touchscreen Housing Material Mounting Dimensions w x h x d...