Preselection 1 Menu
In this menu, the parameters of the reference source, the switching conditions and further definitions for preset value /
switching point 1 are defined.
This function is only available for devices with option CO, AO or RL.
SOURCE 1
This parameter defines the reference source for preselection 1
0 MEASUREM. RESULT
Reference source is the measurement result of the selected operating mode
1 COUNTER A
Reference source is the counter reading of channel A.
(only visible in mode COUNTER
COUNT MODE: A+B or A-B)
2 COUNTER B
Reference source is the counter reading of channel B.
(only visible in mode COUNTER
COUNT MODE: A+B or A-B)
3 BATCH COUNTER
Reference source is the batch counter.
(only visible in mode COUNTER
BATCH / TOTAL MODE:
INCREMENT BATCH, DECREMENT BATCH or USE INPUTS ONLY)
4 TOTAL COUNTER
Reference source is total counter.
(only visible in mode COUNTER
BATCH / TOTAL MODE: TOTAL COUNTER)
5 TOTAL TIMER
Reference source is the total timer.
(only visible in mode TIMER
TOTAL TIME MODE: YES)