Fs340_02b_oi_e.docx / Nov-21
Page 36 / 49
Outputs
No.
Output
Terminal
K1
Error:
This output goes high when an error is detected during operation
(see chapter
“Error
Messages”).
X2 / 26
K2
Alert:
This output is set when during forward motion the carriage
reaches the “Alarm Position”.
It can be used to limit the traveling range of the carriage into
forward direction during production. If, e.g. for mechanical or
other reasons, the carriage could not synchronize with the line,
the controller would never generate the “Ready to cut” signal
and the carriage would run to the front stop. The output switches
high to indicate that the carriage will run out of range if the cut
will not be aborted immediately.
X2 / 25
K3
Home:
Indicates that the carriage is in its home position like defined by
register “Home Window”.
X1 / 10
K4
Ready to Cut:
This output goes high when the shear has reached its cutting
position with respect to the material and moves fully
synchronous with the line. It is reset to low after the controller
has received the “Cut completed” signal.
X1 / 9
–
Max. Correction*:
Indicates that the limitation of the correction voltage has been
activated to keep the
correction inside “Max. Correction”
–
–
Max. Frequency*:
Indicates that the line speed (line encoder frequency) has
exceeded its maximum value as defined by parameter “Max.
Master Frequency”.
–
–
Unit Ready*:
Indicates that the unit is ready to operate after power-up,
initialization and successful self-test.
–
*) Serial readout only (displayed at PC by OS10 operator software)