IX34208a_e.doc / Aug-09
Page 30 / 40
5.5. Testing Functions
The test menu can be accessed while doing the basic set up, as shown in section 4.1. Most of
these tests are for factory use only, but the following tests may also be helpful for the user:
Menu
Selection
Text
Description
Cd (Clock- and data wiring test):
When the wiring of clock line and data line is ok,
the display shows “Cd 11”. Display of “Cd 10”
means that the clock line is o.k. but the data wires
are false (wrong polarity) and "Cd 01" indicates a
problem with the clock lines.
With master mode, only the data lines are subject
of this test.
Cd (Clock- and data function test):
The next test generates clock and data signals and
feeds them directly into the rear terminals.
Therefore please remove the encoder connection.
“Cd iO” says that clock and data interface are all
right. and all other displays indicate a problem
with the SSI interface circuit.
5.6. Error Messages
The unit can detect and display the following errors:
Menu
Selection
Text
Description
Error-bit: the error bit or the power failure bit of
the encoder (PFB) is set
Error-time-out: with Slave mode, during the last
0.6 seconds (plus wait time setting) the unit did
not receive any valid data.
Error-Format: with Slave mode, a telegram with
too short length has been received.