Counter A Settings
In this menu, the settings for the pulse counter (or position indicator) on channel A are defined.
FACTOR
Scaling factor for channel A.
For example: A setting of factor 1.23456 and 100000 input pulses will result in a value of 123456.
0,00001
Smallest value
1
Default value
99,99999
Highest value
SET VALUE
In case of a set/reset command (via keys, Control-Inputs or PC-user interface), the counter of channel A is set to
the value entered here.
-99999999
Smallest value
0
Default value
+99999999
Highest value
DECIMAL POINT
This value defines the position of the decimal point.
0 NO
No decimal point
1 0000000.0
Decimal point at the specified position
2 000000.00
Decimal point at the specified position
3 00000.000
Decimal point at the specified position
4 0000.0000
Decimal point at the specified position
5 000.00000
Decimal point at the specified position
6 00.000000
Decimal point at the specified position
7 0.0000000
Decimal point at the specified position