1.3.

 

Installation 

The device is only allowed to be installed and operated within the permissible temperature range. 
Please ensure an adequate ventilation and avoid all direct contact between the device and hot or 
aggressive gases and liquids.  

 

Before installation or maintenance, the unit must be disconnected from all voltage-sources. 
Further it must be ensured that no danger can arise by touching the disconnected voltage-
sources.

 

 

Devices which are supplied by AC-voltages, must be connected exclusively by switches, 
respectively circuit-breakers with the low voltage network. The switch or circuit-breaker must be 
placed as near as possible to the device and further indicated as separator. 

 

Incoming as well as outgoing wires and wires for extra low voltages (ELV) must be separated 
from dangerous electrical cables (SELV circuits) by using a double resp. increased isolation. 

 

All selected wires and isolations must be conform to the provided voltage- and temperature-
ranges. Further all country- and application-specific standards, which are relevant for structure, 
form and quality of the wires, must be ensured. Indications about the permissible wire cross-
sections for wiring are described in the “Technical Specifications” (see chapter 

6

).  

 

Before first start-up it must be ensured that all connections and wires are firmly seated and 
secured in the screw terminals. All (inclusively unused) terminals must be fastened by turning the 
relevant screws clockwise up to the stop.  

 

Overvoltages at the connections must be limited to values in accordance to the overvoltage 
category II.  

 

For placement, wiring, environmental conditions as well as shielding and earthing/grounding of 
the supply lines the general standards of industrial automation industry and the specific shielding 
instructions of the manufacturer are valid.  

 

Please find all respective hints and rules on 

www.motrona.com/download.html   

--> “[General EMC Rules for Wiring, Screening and Earthing]”. 
 

1.4.

 

Cleaning, Maintenance and Service Notes 

To clean the front of the unit please use only a slightly damp (not wet!), soft cloth. For the rear no 
cleaning is necessary. For an unscheduled, individual cleaning of the rear the maintenance staff 
or assembler is self-responsible.  

 

During normal operation no maintenance is necessary. In case of unexpected problems, failures 
or malfunctions the device must be shipped for back to the manufacturer for checking, adjustment 
and reparation (if necessary). Unauthorized opening and repairing can have negative effects or 
failures to the protection-measures of the unit. 

Summary of Contents for ZX020

Page 1: ...Product Features Miniature panel housing Bright LED display with 6 digits Add on frame for clip or screw mounting Counting frequency 15 to 60 kHz depends on counting mode Selectable filter for use wi...

Page 2: ...in other electronic and printed media as well as in the internet requires prior written authorization by motrona GmbH Table of Contents 1 Safety Instructions and Responsibility 3 1 1 General Safety I...

Page 3: ...e right to modify the hardware software or operation manual at any time and without prior notice Therefore there might be minor differences between the unit and the descriptions in operation manual Th...

Page 4: ...sections for wiring are described in the Technical Specifications see chapter 6 Before first start up it must be ensured that all connections and wires are firmly seated and secured in the screw term...

Page 5: ...ed and additionally press the right one After releasing the keys the display alternates between the parameter title and the setting of the parameter After pressing any key only the parameter value for...

Page 6: ...echnical Specifications chapter 6 on Filter on Maximum counting frequency 30 Hz 3 3 Input Mode of count impulses Input Cnt dir Input A Count input Input B Direction select up down Up dn Differential I...

Page 7: ...by the divider set 99 9999 Setting range 0 0001 to 99 9999 Setting 0 will not be accepted 3 5 Decimal point dP 0 Sets the decimal point of the display 0 000 Max 3 decimal places 3 6 Set Reset mode re...

Page 8: ...99999 Upon a Set Reset command the counter sets to the value entered here 99 9999 Range 199 999 999 999 3 8 End of program Endpro No Select No to return to the beginning of the menu for verification o...

Page 9: ...Page 9 11 4 Terminal Assignments also printed to the top of the unit 5 Delivery includes Panel mounting clip Bezel for screw mounting with panel cut out 50 x 25 mm Bezel for clip mounting with panel c...

Page 10: ...git height Range 6 digit LED red 8 mm 0 3149 inch 199999 999999 Housing Material Mounting Dimensions Miscellaneous Protection class Weight plastic panel cut out w x h 45 x 22 mm resp 1 772 x 0 866 inc...

Page 11: ...0 157 6 5 0 256 59 0 2 323 22 x45 48 0 1 890 24 0 945 22 2 0 3 45 0 0 6 1 772 0 024 0 874 0 012 max 0 76 25 0 x 50 0 53 0 2 087 26 0 1 024 1 0 0 039 4 0 0 157 25 0 0 5 50 0 0 6 0 984 x 1 969 1 969 0...

Reviews: