99342ENG - REV. 00

- Connection controlled by power transformer

The lock can be controlled via a wet connection coming from the lock transformer (12-24V AC). Pins 1 and 2 are used for 

the device power supply (no set polarity); pin 4 is used for the button input;

- Connection controlled by power supply

The unlock command can be an electric impulse sent to the POSITIVE pole of the lock power supply.

- Connection with two separate power sources

In this case, the lock’s power source (12-24V AC/DC) can be different from the source of the unlocking command            

impulse. There is no set polarity for the power supply (pins 1 and 2) and unlocking command impulse (pins 3 and 4).

Transformer or 

Power supply 

12 - 24 V (AC / DC)

Transformer or 

Power supply

12 - 24 V (AC / DC)

Button

Lock

        Power supply 

       12 - 24 V  DC

Transformer   

12 - 24 V  AC

Button

Lock

Button

- Button connection using dry contact

In this configuration the lock is controlled using a dry (volt-free) contact. The button must therefore be connected to 

pins 5 and 6 of the disconnectable terminal (no set polarity).  The lock can be powered by 12 to 24V DC or AC current.

Transformer or 

Power supply

12 - 24 V (AC / DC)

Button

Lock

N.B.: The lock must not be operated mechanically when activated electrically.

Third wire to be added 

in case of replacement 

with an electric lock

Third wire to be added 

in case of replacement 

with an electric lock

Lock

Summary of Contents for XDRIN 49XD1 Series

Page 1: ...covers the replacement or repair of parts found defective at origin due to manufacturing defects Costs of shipping to and from service centres will be paid by the customer In case of repeated malfunc...

Page 2: ...ck using the existing plates holes Mount the lock according to the following procedure Unscrew the side screws and remove the cover Fig 4 Attach the lock and the strike plate using the supplied screws...

Page 3: ...ING THE GRACE PERIOD The grace period is the amount of time within which the door must be opened measured from the moment the button has been pressed If the door has not been opened within the set gra...

Page 4: ...re is no set polarity for the power supply pins 1 and 2 and unlocking command impulse pins 3 and 4 Transformer or Power supply 12 24 V AC DC Transformer or Power supply 12 24 V AC DC Button Lock Power...

Page 5: ...lse on Terminal 4 The lock can be powered by a 12 to 24V current Bus based connection to the control unit two wires via a dry contact relay In this configuration the lock is controlled by a dry contac...

Page 6: ...ternal escutcheons JAMMING ERRORS In the event of jamming due to mechanical problems that prevent proper bolting the lock will automatically proceed to make 5 additional locking attempts If none of th...

Page 7: ...linder with cylinders of the same type e g of the same master system If the gate thickness is greater than the cylinder length you can use the special extension KIT optional code 98C47ES001 CHANGING T...

Page 8: ...ds with 5 second increments Door bolted signal Red green dual colour LED Protection rating IP44 DRAWINGS AND TECHNICAL SPECIFICATIONS External cylinder extension kit cod 98C47ES001 REPLACING AN INTERN...

Page 9: ...www mottura it 99342ENG REV 00 07 18 a_020258 Internal cylinder version 49XD1 Internal knob version 49XD2...

Reviews: