background image

8

1

2

3

7

  9

8

99342ENG - REV. 00

Power supply

From 12 to 24V AC/DC

Versions

Right-hand or left-hand knob/cylinder 
Right-hand or left-hand cylinder/cylinder 

Entry 

Adjustable 50 - 60 - 70 mm 

Max. power absorption 
(during motor stall)

500mA

Holding current 

30mA 

Operating temperature 

From -25°C to 80°C 

Automatic relocking grace 
period 

Adjustable from 5 to 60 seconds with 
5-second increments 

Door bolted signal 

Red/green dual colour LED 

Protection rating 

IP44 

DRAWINGS AND TECHNICAL SPECIFICATIONS

External cylinder extension

kit cod. 98C47ES001

REPLACING AN INTERNAL CYLINDER 

Unscrew the side screws and remove the cover (Fig. 1). 

Remove the tailpiece by unscrewing the two highlighted screws (Fig. 2), remove the existing cylinder by unscrewing 

the 2 screws (Fig. 3).

Install the new cylinder, then reassemble the tailpiece and replace the cover.

Right-hand version

From 50 to 105 mm

Mottura-made 

cylinders

Other cylinder 

types

Summary of Contents for XDRIN 49XD1 Series

Page 1: ...covers the replacement or repair of parts found defective at origin due to manufacturing defects Costs of shipping to and from service centres will be paid by the customer In case of repeated malfunc...

Page 2: ...ck using the existing plates holes Mount the lock according to the following procedure Unscrew the side screws and remove the cover Fig 4 Attach the lock and the strike plate using the supplied screws...

Page 3: ...ING THE GRACE PERIOD The grace period is the amount of time within which the door must be opened measured from the moment the button has been pressed If the door has not been opened within the set gra...

Page 4: ...re is no set polarity for the power supply pins 1 and 2 and unlocking command impulse pins 3 and 4 Transformer or Power supply 12 24 V AC DC Transformer or Power supply 12 24 V AC DC Button Lock Power...

Page 5: ...lse on Terminal 4 The lock can be powered by a 12 to 24V current Bus based connection to the control unit two wires via a dry contact relay In this configuration the lock is controlled by a dry contac...

Page 6: ...ternal escutcheons JAMMING ERRORS In the event of jamming due to mechanical problems that prevent proper bolting the lock will automatically proceed to make 5 additional locking attempts If none of th...

Page 7: ...linder with cylinders of the same type e g of the same master system If the gate thickness is greater than the cylinder length you can use the special extension KIT optional code 98C47ES001 CHANGING T...

Page 8: ...ds with 5 second increments Door bolted signal Red green dual colour LED Protection rating IP44 DRAWINGS AND TECHNICAL SPECIFICATIONS External cylinder extension kit cod 98C47ES001 REPLACING AN INTERN...

Page 9: ...www mottura it 99342ENG REV 00 07 18 a_020258 Internal cylinder version 49XD1 Internal knob version 49XD2...

Reviews: