11.1 - DOUBLE TUBE VERSION (Art. 99.703)  

To replace the batteries, open the door and insert a screwdriver (or a coin) in the notches on the two covers. Press gently and turn them counter-
clockwise until they come out, as shown in the figure. Remove the batteries (three in each tube). If the bottom battery doesn’t come out, press on 
it gently with the screwdriver and release it suddenly so that the spring (which pushes from behind the battery) will expel it completely. Replace 
the batteries, inserting them with the negative pole (-) in the direction of insertion and the positive pole (+) facing the cover.

When insertion is done, close the covers by repeating the above steps in the reverse order.

10 - MAINS POWER SUPPLY

11 - BATTERY POWER SUPPLY

If the lock is powered from the MAINS, you have to use an appropriately sized transformer.
The MOTTURA transformer (AC/DC Adapter option Art. 99.683 with cable Art. 99697) was subjected to tests on the lock to obtain the legally 
required certifications regarding immunity from electrical and electromagnetic noise as well as emissions to the mains and to the environment. 
Therefore, it must be used to power lock versions that require a transformer.
The use of any transformer other than the one supplied (even for temporary testing), in addition to creating risk of damaging the lock or causing 
malfunctions, will immediately void all warranties. Mottura serrature di sicurezza S.p.A. will assume no liability for any harm/damage caused to 
persons or property.

If the lock is powered by BATTERIES, you have to use a battery pack (option Art. 99.703 or Art. 99.704) plus a battery charger (option Art. 99.711 
with cable Art. 99.712) if rechargeable batteries are used. The system automatically checks the battery charge level at the start of every cycle. 
When the batteries are near the minimum level sufficient to ensure correct functioning of the lock, 3 beeps and lighting of the YELLOW LED on the 
internal escutcheon remind you to replace them. In this condition, correct operation of the lock and correct scanning of transponder keys are not 
guaranteed. When the battery charge is no longer sufficient to operate the lock, a double high-low sound and lighting of the YELLOW LED require 
their replacement. In any case, you should replace the batteries once a year. 
Follow these instructions when replacing the batteries:

Never use rechargeable batteries if your system requires non-rechargeable (alkaline) batteries. Doing so will compromise operation of 
the lock. Never use non-rechargeable (alkaline) batteries if your system requires rechargeable batteries. Doing so will create risks of 

overheating, bursting, and acid leaks.
Mottura serrature di sicurezza S.p.A. assumes no liability for any type of malfunction, fault, and harm/damage caused to persons or 

property deriving from failure to observe the following instructions, which will also void the warranty.

For non-rechargeable alkaline batteries

 - 6x1.5V type D (flashlight): replace all alkaline batteries promptly (or at least once a year) as soon as the 

lock signals that their charge is insufficient to prevent electronic malfunction, failure to open the door, or damage.

For rechargeable NiMH batteries

 - 6x1.2V NiMH 2200mAh D (flashlight): use the Mottura code 99.711 battery charger and promptly replace all 

rechargeable batteries if the lock signals that their charge is insufficient for a few consecutive days. If insufficient charge is signaled occasionally, 
this does not mean that they have to be replaced: they may not have been sufficiently recharged after a power failure or very frequent use of the 
lock. In this case, recharge the batteries for at least 8 hours and use the lock electrically as little as possible, then check the charge level as described 
in paragraph 9.1.
In both cases, all of the batteries must be replaced at the same time, with new ones of the same brand and model. When replacing the 6 batteries, 
be extremely careful to respect their polarity in order to avoid permanent damage.
The battery pack is available in two versions: double tube or cassette.

ATTENTION: Drained batteries are harmful to the environment!!
They must be disposed of in special containers found wherever batteries are sold, as required by law.

Summary of Contents for Xmode F1.0

Page 1: ...POWERED ELECTRONIC LOCK OPERATION AND MAINTENANCE INSTRUCTIONS USER MANUAL GLUE THE LOCK SYSTEM CODE LABEL HERE SYSTEM CODE RECHARGEABLE M 2 0 F1 0 ...

Page 2: ...SABLING SERVICE TAG KEYS 5 4 RESETTING SERVICE TAG KEYS 5 5 DELETING INDIVIDUAL TAG KEYS 5 6 DELETING ALL TAG KEYS 6 LOCK OPERATION MODES 10 6 1 PROGRAMMING LOCK OPERATION MODES 6 2 ACTIVATING DEACTIVATING THE SECURITY CODE FROM THE INSIDE 7 LOCK OPERATION WITH TAG KEYS 11 8 LOCK OPERATION WITH KEYPAD AND TAG KEYS 12 8 1 MEMORIZING PERSONAL ACCESS CODES 8 2 DELETING A PERSONAL ACCESS CODE 8 3 DELE...

Page 3: ...nctions of the same type or unrepairable defects Mottura Serrature di Sicurezza S p A may at its own discretion replace the complete product The warranty on the replaced product will continue until expiration of the original warranty If work is necessary at the customer s home the customer will be required to pay a charge for the costs of transfer of authorized technical person nel Transport will ...

Page 4: ...BLUELEDsteadyon gridpower GREENLEDsteadyon power batteriesefficient BLUE LED steady on GREEN steady on grid battery power YELLOWLEDsteadyon 3beeps remindertoreplacebatteries YELLOWLEDsteadyon doublehigh lowsound batteriesdrained The reminder to replace the batteries is given before any operation is done opening closing etc You should replace the batteries as soon as possible to ensure correct fun ...

Page 5: ...ad lets you enter a PIN 3 to 8 digits with which to operate the lock transponder key TAG the escutcheon checks the presence of a transponder key TAG positioned close to the MM logo at the bottom zone B The function keys are number keys to enter codes P Programming to enter the programming phase E Enter to open close the door after entering the code in normal use confirms a selection in programming...

Page 6: ...e TAG has the transponder inserted in a card in the center In a free TAG system the card is ORANGE In a Protected TAG system the card is YELLOW and shows the number ex M0001 F0001 of the system to which it belongs followed by the key code To prevent the shell from being damaged as a result of continuous opening and closing the key inside the shell should be used ONLY in emergen cies power failure ...

Page 7: ...the system memory see paragraph 5 6 then re memorize all of the TAGs remaining in your possession see paragraphs 5 1 5 2 accor ding to the required hierarchy master service If a TAG with integrated key is lost or stolen you should replace the cylinder and keys as well If aTAG with duplicates TAG with same code is lost or stolen you have to completely delete all of the TAGs in the system memory see...

Page 8: ... UP arrow key and then place theTAG that you want to program at master level close to the exter nal escutcheon scanner A multi tone sound from the buzzer confirms that the TAG has been memorized in this phase the LEDs can be ignored because they indicate the status enabled disabled of the service TAGs In case of error the buzzer gives a rapid double high low sound with flashing of the YELLOW LED i...

Page 9: ...the buzzer sounds about 3 seconds Keep the TAG to be deleted close to the external escutcheon scanner and simultaneously keep E pressed on the internal escutcheon for at least 3 seconds The buzzer will give a long sound to confirm that the TAG has been deleted In case of error it will give an alternating bi tonal sound if the TAG is not in the internal databa se or 5 beeps ONLY in a FREE TAG SYSTE...

Page 10: ...loses the bolts LATCHBOLTS ONLY When an operation is requested if the lock was closed it opens the bolts if it was open it closes the bolts The spring latch is never operated electronically to open the door you have to operate it manually with the handle This operating mode requires the spring latch handle to be present on both sides of the door Enter programming mode as described in point 4 Press...

Page 11: ...ide to prevent children or strangers from opening closing the door The code consists of a sequence of 1 to 4 combinations of the UP arrow key and the DOWN arrow key needed to open close the lock instead of the usual enter E key The buzzer gives a long beep to confirm that the security code has been activated To open close the lock from the inside you have to enter the selected code and then press ...

Page 12: ...reset code Enter programming mode as described in point 4 Press the P key to enter code programming mode Enter a code composed of a minimum of 3 to a maximum of 8 digits then confirm by pressing E The flashing GREEN LED accompanied by 3 high low sounds confirm that the code has been memorized The flashing RED LED accompanied by 2 high low sounds means that the entered code is already in memory The...

Page 13: ...ans of the internal escutcheon for escutcheon display refer to the appropriate instruction manual provided with the article you can always check the type of power supply and in case of battery power check the charge level In systems with rechargeable batteries disconnect the 230 VAC main power supply to switch off the battery charger and wait AT LEAST 15 seconds before continuing note the BLUE LED...

Page 14: ...orrect operation of the lock and correct scanning of transponder keys are not guaranteed When the battery charge is no longer sufficient to operate the lock a double high low sound and lighting of theYELLOW LED require their replacement In any case you should replace the batteries once a year Follow these instructions when replacing the batteries Never use rechargeable batteries if your system req...

Page 15: ...MOTE CONTROL MANUAL N B Do not connect any type of voltage to the cable doing so will permanently damage the lock 13 NOTES ON USING THE SERVICE CYLINDER 14 NOTES ON USING THE MASTER CYLINDER Top position It is designed to overcome power failures or possible malfunctions of the electronic part Therefore it is preferable not to use it in normal operating conditions It must never be used when the loc...

Page 16: ...gistered Enter the programming menu and register the tran sponder After pressing the E key on the internal escutcheon there is an immediate single low sound The lock is communicating with another device con nected to it on the RS485 communication line The lock is in programming phase Wait for the dialog to end and for the lock to return to stand by then try the operation again Exit programming and...

Page 17: ...LLOW steady on 3 beeps CHECK TYPE OF POWER GREEN LED RED LED BLUE YELLOW LED BUZZER INTERNAL ESCUTCHEON Fixed BATTERY BLUE steady on MAINS PROGRAMMING GREEN LED RED LED BLUE YELLOW LED BUZZER INTERNAL ESCUTCHEON Fixed Fixed 3 beeps EXTERNAL ESCUTCHEON Fixed Fixed 3 beeps MASTER TAG ACTIVATION GREEN LED RED LED BLUE YELLOW LED BUZZER INTERNAL ESCUTCHEON multi tone sound Activation YELLOW flashing d...

Page 18: ...activation ACTIVATION OF NUMERICAL KEYPAD CODES GREEN LED RED LED BLUE YELLOW LED BUZZER EXTERNAL ESCUTCHEON Flashing 3 low high sounds memorization Flashing 2 low high sounds code already inserted Flashing 2 low high sounds insertion error DELETION OF NUMERICAL KEYPAD CODES GREEN LED RED LED BLUE YELLOW LED BUZZER EXTERNAL ESCUTCHEON Flashing 3 high low sounds deletion Flashing 2 low high sounds ...

Page 19: ...19 NOTE ...

Page 20: ...99286GB 06 14 a_013334 SAFEGUARDINGYOUR SECURITY www mottura it ...

Reviews: