14
ess MBP 2.5 / MBP 4.0 MOuntain Man Owner’s Manual
Trigger
the trigger turns the spray on and off. it can be continuously held for
operation or it can be locked in place.
Brass Bolt
Pull Trigger Lock
forward to engage
Depress Trigger
to spray
To engage/disengage the trigger:
1. Depress the trigger up towards the body of the spray gun
to start spraying.
2. to keep spraying, either keep holding the trigger or lock it
in place by pulling up the lock and hooking the trigger.
3. to stop spraying when the trigger is not locked, let go of
the trigger.
To clean the trigger:
1. unthread the brass bolt on the top of the spray gun with a
5/8” socket wrench. Be careful not to lose the spring, plunger,
copper washer, and small brass bushing inside the trigger.
note how they fit inside so they may be replaced properly.
2. Check inside the trigger for blockage. Clean out any debris
with compressed air or warm, soapy water.
3. replace the spring and plunger; rethread the brass bolt into
the top of the spray gun until tight.