View/Change the Pre-set Torque Value:
1. Press either target key once to see the current target value without making
any changes. The target will show for 3 seconds.
2. Press and hold the Target - button to lower the current target value. Press
and hold the button to increase the current target value. The
longer you press and hold the target key the faster the display will change.
When you apply torque with a target set:
As you get close to the target torque value you will see a yellow light
warning you that you are approaching the target value.
When you are within 2% of the target value you will see a green light and
hear a buzzer. Stop pulling!
When you go over 2% of the target value you will see a red light and hear
an intermittent buzzer. Too much torque!
Changing Units:
1. Press the Units button to select different torque units: ft.lb.......In.lb.......Nm
Notes
: When you change units the target setting will also be changed to the
new units value (makes a great torque conversion calculator).
The units selected will become the default units when the wrench is turned off
and on again.
Changing from Peak to Track mode:
1. Press and hold the “Power Clear” button when the wrench is on.
2. Press the “Target - ” button to change mode from Peak to Track while you
hold the power/clear button.
Press & hold to decrease
pre-set torque.
Press & hold to increase
pre-set torque.
Press to change units
Press & hold Power & Clear