background image

RETW Operation instructions

Page 2

Mountz Inc.

www.etorque.com

View/Change the Pre-set Torque Value:

1. Press either target key once to see the current target value without making 

any changes. The target will show for 3 seconds.

2. Press and hold the Target - button to lower the current target value. Press 

and hold the  button to increase the current target value. The 
longer you press and hold the target key the faster the display will change.

When you apply torque with a target set:

As you get close to the target torque value you will see a yellow light 
warning you that you are approaching the target value.

When you are within 2% of the target value you will see a green light and 
hear a buzzer. Stop pulling!

When you go over 2% of the target value you will see a red light and hear 
an intermittent buzzer. Too much torque!

Changing Units:

1. Press the Units button to select different torque units: ft.lb.......In.lb.......Nm

Notes

: When you change units the target setting will also be changed to the

new units value (makes a great torque conversion calculator).

The units selected will become the default units when the wrench is turned off
and on again.

Changing from Peak to Track mode:

1. Press and hold the “Power Clear” button when the wrench is on.

2.  Press the “Target - ” button to change mode from Peak to Track while you 

hold the power/clear button.

Press & hold to decrease 
pre-set torque.

Press & hold to increase 
pre-set torque.

Press to change units

Press & hold Power & Clear

Press Target - to change modes

Summary of Contents for RETW

Page 1: ...rate Headquarters 1080 North 11th Street San Jose CA 95112 Phone 408 292 2214 Fax 408 292 2733 www etorque com Mountz Inc ISO 9001 2000 company R E T W R E T W Electronic Click Wrench Operating Instructions ...

Page 2: ...BATT icon will light When batteries are critically low the wrench will not turn on It is OK to use externally rechargeable batteries Battery life depends on battery quality and the amount the lights and buzzer are used target torque Keep the end cap threads clean and dry for a good contact Power On 1 Press and hold the power button to turn the wrench on Notes If you do not use the wrench for 3 min...

Page 3: ...target value you will see a green light and hear a buzzer Stop pulling When you go over 2 of the target value you will see a red light and hear an intermittent buzzer Too much torque Changing Units 1 Press the Units button to select different torque units ft lb In lb Nm Notes When you change units the target setting will also be changed to the new units value makes a great torque conversion calcul...

Page 4: ...g a steady even pull using built in ratchet as necessary Wrench should be kept at 90 degrees to axis of bolt during tightening 2 When pre set torque is reached there are 3 ways to determine what torque is being applied Look directly at the LCD Pre set torque and look for the lights Pre set torque and listen for the buzzer 3 Once pre set torque is achieved do not apply any more torque or you will o...

Page 5: ... sent automatically when the wrench clears or when the clear key is pressed Sending Data to a Computer 1 Plug the RS232 adapter in any 9 pin serial com port on your computer 2 Data is sent standard ASCII format Protocol 9600 Bps 8 1 n Information Sent comma separated values Torque value Units Pre set torque setting Tolerance setting Under Pass Over pre set torque Press the Power button to turn off...

Page 6: ...or can use the wrench on external power without batteries The operator can charge the batteries while the Rs232 Power adapter is plugged into a computer while you are sending data to the computer Hyperterminal 1 To Open Hyperterminal Select A Start B Programs C Accessories D Communications E Communications 2 Name the new file 3 Select Properties 4 Select Connect Com X Where X is the active com por...

Page 7: ...cy it is crucial that torque control measuring equipment be calibrated regularly We recommend a general once a year calibration interval However it is the user s organization that must determine suitable intervals based upon equipment performance application degree of usage and management objectives For calibration re adjustment or repairs please send the tool to one of our 3 service locations Acc...