Changing Tolerance Settings:

1. The default setting is +/- 2% of pre-set torque. The operator can adjust the 

the setting from 1 - 10% or turn it off.

2.  With the wrench ON, hold the power button and press the “” key.  

Keep pressing the “” key until you show the desired value.

3.  The tolerance setting provides a visual and sound signal if the torque 

Passed or Failed.
- If the torque is under the pre-set torque & tolerance setting - Yellow light
- If the torque is within the pre-set torque & tolerance setting - Green light
- If the torque is over the pre-set torque & tolerance setting - Red light

Applying Torque:

1. Tighten nut or bolt by applying a steady even pull using built in ratchet as 

necessary. Wrench should be kept at 90 degrees to axis of bolt during 
tightening. 

2. When pre-set torque is reached, there are 3 ways to determine what torque 

is being applied:
- Look directly at the LCD.
- Pre-set torque and look for the lights.
- Pre-set torque and listen for the buzzer.

3.  Once pre-set torque is achieved, do not apply any more torque or you will 

over tighten it.

LCD Contrast:

1. The operator can change the LCD contrast (viewing angle) by first pressing

and holding the Units button and then press the “” button.  This is 
useful when the temperature is very cold or very hot.

Notes:

The contrast changes very slowly, so be patient.

Press & hold to Power Clear
button with the wrench on

Press the “” button to
change tolerance setting

Press & hold to Units button
with the wrench on

Press the “” button 
(wait for the contrast to change)

Summary of Contents for RETW

Page 1: ...rate Headquarters 1080 North 11th Street San Jose CA 95112 Phone 408 292 2214 Fax 408 292 2733 www etorque com Mountz Inc ISO 9001 2000 company R E T W R E T W Electronic Click Wrench Operating Instructions ...

Page 2: ...BATT icon will light When batteries are critically low the wrench will not turn on It is OK to use externally rechargeable batteries Battery life depends on battery quality and the amount the lights and buzzer are used target torque Keep the end cap threads clean and dry for a good contact Power On 1 Press and hold the power button to turn the wrench on Notes If you do not use the wrench for 3 min...

Page 3: ...target value you will see a green light and hear a buzzer Stop pulling When you go over 2 of the target value you will see a red light and hear an intermittent buzzer Too much torque Changing Units 1 Press the Units button to select different torque units ft lb In lb Nm Notes When you change units the target setting will also be changed to the new units value makes a great torque conversion calcul...

Page 4: ...g a steady even pull using built in ratchet as necessary Wrench should be kept at 90 degrees to axis of bolt during tightening 2 When pre set torque is reached there are 3 ways to determine what torque is being applied Look directly at the LCD Pre set torque and look for the lights Pre set torque and listen for the buzzer 3 Once pre set torque is achieved do not apply any more torque or you will o...

Page 5: ... sent automatically when the wrench clears or when the clear key is pressed Sending Data to a Computer 1 Plug the RS232 adapter in any 9 pin serial com port on your computer 2 Data is sent standard ASCII format Protocol 9600 Bps 8 1 n Information Sent comma separated values Torque value Units Pre set torque setting Tolerance setting Under Pass Over pre set torque Press the Power button to turn off...

Page 6: ...or can use the wrench on external power without batteries The operator can charge the batteries while the Rs232 Power adapter is plugged into a computer while you are sending data to the computer Hyperterminal 1 To Open Hyperterminal Select A Start B Programs C Accessories D Communications E Communications 2 Name the new file 3 Select Properties 4 Select Connect Com X Where X is the active com por...

Page 7: ...cy it is crucial that torque control measuring equipment be calibrated regularly We recommend a general once a year calibration interval However it is the user s organization that must determine suitable intervals based upon equipment performance application degree of usage and management objectives For calibration re adjustment or repairs please send the tool to one of our 3 service locations Acc...