RETW Operation instructions
Page 4
Mountz Inc.
www.etorque.com
Manual Off:
1. To manually turn off the wrench, hold the Power button for 3 seconds.
Accessories
Item #
260114
Model:
RS-232 and Rechargeable Battery Adapter Kit
- Charge NimH batteries while using the wrench
- Use the wrench on external power (no batteries)
- Send torque information to a printer, computer, data logger (Data is sent automatically when the wrench clears or
when the clear key is pressed)
Sending Data to a Computer:
1. Plug the RS232 adapter in any 9 pin serial com. port on your computer.
2. Data is sent standard ASCII format. Protocol: 9600 Bps, 8,1,n
Information Sent (comma separated values):
- Torque value
- Units
- Pre-set torque setting
- Tolerance setting (%)
- Under/Pass/Over pre-set torque
Press the Power button to turn
off wrench.
110V Wall Transformer
RS-232Serial/Power Adapter
Data/Charge Cable
Output example:
Actual torque Tolerance Setting
+015.1 ft-lbs +040.0 2% Low
Pre-set torque Torque Status