background image

STC30 Plus (v4.3) Transformer

(Rev 3.0  9/9/11)

Connector and Cables (These cables are included with Scout Screw Counter)

Cable for connecting Scout to the STC30 Plus (Item #14-801120)

1

2

3

4

5

6

Signal Cable 

Pin No.

Color

Function

1

Solid Orange

Not Used

2

White/Orange

Stop

3

Blue

Start

4

White/Blue

DC(-)

5

Green

Driver Lock

6

White/Green

Driver Lock

7

Brown

N/A

8

White/Brown

Not Used

RJ-11

Modular Jack

2M

1.5M

Corporate Headquarters: 

1080 North 11th Street, San Jose, CA 95112    Phone: (408) 292-2214   Fax: (408) 292-2733

www.mountztorque.com

Page 4

1

5

4

3

2

1: Motor (+)
2: Limit
3: Motor (-)
4: Drive
5: Ground

Output Pin Connection

Note!

Do not connect any other electric screwdriver that’s not
listed to be used with the transformer. It may cause
electric shock, fire, damage to the tools or operator
injury.

Input voltage selection

110V

110VAC Selected

230V

230VAC Selected

110V

230

Timing chart for Start / Stop Signal

Start

Stop

0.25 Sec

7

8

Summary of Contents for STC 30 Plus v4.3

Page 1: ...s v4 3 Operation Instructions Corporate Headquarters 1080 North 11th Street San Jose CA 95112 Phone 408 292 2214 Fax 408 292 2733 www mountztorque com RoHS Power Supply for Electric Screwdrivers Rev 3...

Page 2: ...rt Mode Press the sT button in the lower bottom right The power light will blink once and turn Yellow which indicates that you are in Soft Start mode There are 4 different time settings for the Soft S...

Page 3: ...ill shut down automatically when the current exceeds 12 13A The controller should be reset by turning off the power switch for one minute and turned back on If the current is not over the limit power...

Page 4: ...White Brown Not Used RJ 11 Modular Jack 2M 1 5M Corporate Headquarters 1080 North 11th Street San Jose CA 95112 Phone 408 292 2214 Fax 408 292 2733 www mountztorque com Page 4 1 5 4 3 2 1 Motor 2 Limi...

Page 5: ...ue stripe Green stripe PLC connections Electric Screwdriver STC30 Plus Scout Screw Counter PLC PLC Signal Out Cycle End NG OK Buzzer Signal In Cycle Start Driver Lock Signal In Driver Lock Signal Out...

Page 6: ...4 3 STC 40 Model U 3B Item 145753 Size WxDxH 3 x 2 3 8 x 1 Weight 3 6 oz Types of Signals Open Collector by Opto Coupler Reversed Relay Contact Normal Close Relay Contact Normal Open Opto Coupler 12 2...

Page 7: ...STC30 Plus v4 3 Transformer Rev 3 0 9 9 11 Corporate Headquarters 1080 North 11th Street San Jose CA 95112 Phone 408 292 2214 Fax 408 292 2733 www mountztorque com Page 7...

Page 8: ...ck within its tolerance Torque testers can also be used for quick tools tests on the line or in the lab to determine whether torque tools are holding a given setting A regular torque tool calibration...

Reviews: