TESTING & SERVICING
The manufacturer guar-
antees a torque wrench
accuracy of +/- 4% to the
scale value in question at a
stress cycle of max. 5000.
It is therefore necessary
that you test your torque
wrench at least every 5000
stress cycles on a traceable
calibrated testing device.
For the testing of your
tool we recommend
torque analyzer
testing equipment.
For information
contact Mountz Inc.
or simply call our
Service-Hotline.
Your torque wrench has
to be calibrated at least
once a year. Re-adjust-
ments should only be
carried out either by autho-
rised personnel, accredited
calibration labs or the
manufacturer.
For calibration, re-
adjustment or repairs
we recommend the
service department
of Mountz Inc., the
in-house calibration
lab.
Before a longer period
of non-utilisation the
compression spring of
your torque wrench needs
to be released. Turn the
torque back to the small-
est value on the scale.
Protect your torque
wrench from dust, dirt and
sand by placing it back in
the box after use and store
it in a dry, clean place.
Clean your torque
wrench on the outside
with a dry, clean cloth.
Do not use cleaning spirit
or any other chemical
solvents as these interfere
with the permanent lubri-
cation of the mechanism.
9
DIVISIONS
TORQUE WRENCH
Graduation
Graduation - collar
# !
TITAN
100i
1/4“
20-100 lbf
•
in
5 lbf
•
in
no collar
250i
3/8“
50-250 lbf
•
in
10 lbf
•
in
1 lbf
•
in
75F
3/8“
10-75 lbf
•
ft
2.5 lbf
•
ft
0.25 lbf
•
ft
150F
1/2“
30-150 lbf
•
ft
5 lbf
•
ft
0.5 lbf
•
ft
300F
1/2“
60-300 lbf
•
ft
10 lbf
•
ft
1 lbf
•
ft
600F 3/4“ 120-600 lbf
•
ft 10 lbf
•
ft 1 lbf
•
ft
TITAN